Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 378

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Highly stretchable, anti-corrosive and wearable strain sensors based on the PDMS/CNTs decorated elastomer nanofiber composite

Wang, Ling, Chen, Yang, Lin, Liwei, Wang, Hao, Huang, Xuewu, Xue, Huaiguo, Gao, Jiefeng·2019·Chemical Engineering Journal

Abstract

Abstract Conductive polymer composite based strain sensors have promising applications in the fields of artificial skin, wearable health-care device, etc. However, fabrication of strain sensors with good stretchability, anti-corrosion, excellent durability and reliability remains challenging. In this work, a superhydrophobic strain sensor based on conductive thermoplastic polyurethane/carbon nanotubes/polydimethylsiloxane (TPU/CNTs/PDMS) was prepared by ultrasonication induced CNTs decoration onto the electrospun TPU nanofiber surface, followed by the PDMS modification. Uniformly dispersed CNTs on the nanofiber surface with a hierarchical structure construct the conductive network. The PDMS layer with a low surface energy endows the nanofiber composite with superhydrophobicity thus anti-corrosion property. The introduction of CNTs/PDMS improves both the Young's modulus, tensile strength and the elongation at break. The superhydrophobicity and conductivity can be maintained after the cyclic stretching-releasing test, displaying excellent durability. When used as a wearable strain sensor, the nanofiber composite is capable of detecting body motion and could work even under harsh conditions (moisture, acid and alkaline environment), showing promising application in wearable electronics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.cej.2019.01.014

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 378

Metadata

Authors
Wang, L., Chen, Y., Lin, L., Wang, H., Huang, X., Xue, H., & Gao, J.
Venue
Chemical Engineering Journal
Publisher
Elsevier BV
Published
2019-04
Volume
362
Pages
89-98
ISSN
1385-8947 (ISSN-L)
OpenAlex
W2907048532
Cited by
378
References
24
FWCI
17.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Highly stretchable, anti-corrosive and wearable strain sensors based on the PDMS/CNTs decorated elastomer nanofiber composite. https://app.cochat.ai/papers/10.1016/j.cej.2019.01.014
The paper
Wang, L., Chen, Y., Lin, L., Wang, H., Huang, X., Xue, H., & Gao, J. (2019). Highly stretchable, anti-corrosive and wearable strain sensors based on the PDMS/CNTs decorated elastomer nanofiber composite. Chemical Engineering Journal. https://doi.org/10.1016/j.cej.2019.01.014

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.