The DOI matches its Crossref record.
Electrochemical denitrification of highly contaminated actual nitrate wastewater by Ti/RuO2 anode and iron cathode
Abstract
The main objective of denitrification process is to obtain N2 as the final product by reduction of NO3− along with simultaneous oxidation of by-products like NH4+ and NO2−. In this study, Ti/RuO2 and Fe were used as anode and cathode, respectively, for the treatment of actual wastewater containing high concentration of nitrate ion. The current density (J = 142.86–428.57 A/m2), wastewater pH (4–12) and time (t = 15–180 min) were the main studied operating parameters for the electrochemical (EC) reduction and oxidation of real industrial wastewater containing nitrate (NO3−), ammonium ion (NH4+) and chloride. Faraday law was applied for the calculation of specific energy consumption (SEC) during the process. The maximum NO3− reduction efficiency of ≈46% was obtained at J = 214.29 A/m2 after 180 min with SEC = 149.7 kWh/kg NO3− reduced. Maximum total nitrogen (TN) removal efficiency of ≈51% was obtained at pH = 12 and J = 285.71 A/m2 with SEC = 220.7 kWh/kg NO3− reduced. The reaction mechanism and pathway was established for the EC reduction of NO3− and oxidation of NH4+ and NO2− simultaneously. Field emission scanning electron microscope (FE-SEM) coupled with energy dispersed X-ray (EDX), atomic force microscopy (AFM) and X-ray diffraction (XRD) were used for the characterization of electrodes before and after wastewater treatment. Reaction intermediates were identified by using gas chromatograph coupled with mass spectroscopy (GC/MS). Operational cost analysis for this wastewater has been done on the basis of lab scale reactor and compared with previously reported for other industrial wastewater. Interestingly no sludge and/or scum was produced during the treatment. This study provides better understanding of the reduction of NO3− as well as further oxidation of by-products.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrocatalytic Nitrate Reduction for Sustainable Ammonia Production
van Langevelde, P. H., Katsounaros, I., & Koper, M. T. M. (2021) · Joule · doi:10.1016/j.joule.2020.12.025 · Cited by 1,378
Chen, F.-Y., Wu, Z.-Y., Gupta, S., Rivera, D. J., Lambeets, S. V., Pecaut, S., Kim, J. Y. T., Zhu, P., Finfrock, Y. Z., Meira, D. M., et al. (2022) · Nature Nanotechnology · doi:10.1038/s41565-022-01121-4 · Cited by 1,171
Electrochemical Nitrate Reduction: Ammonia Synthesis and the Beyond
Xiong, Y., Wang, Y., Zhou, J., Liu, F., Hao, F., & Fan, Z. (2024) · Advanced Materials · doi:10.1002/adma.202304021 · Cited by 701
Advanced oxidation processes for water disinfection: Features, mechanisms and prospects
Chen, Y.-D., Duan, X., Zhou, X., Wang, R., Wang, S., Ren, N.-Q., & Ho, S.-H. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.128207 · Cited by 374
Gao, J., Jiang, B., Ni, C., Qi, Y., & Bi, X. (2020) · Chemical Engineering Journal · doi:10.1016/j.cej.2019.123034 · Cited by 352
Metadata
- Authors
- Chauhan, R., & Srivastava, V. C.
- Venue
- Chemical Engineering Journal
- Publisher
- Elsevier BV
- Published
- 2020-04
- Volume
- 386
- Pages
- 122065
- ISSN
- 1385-8947 (ISSN-L)
- OpenAlex
- W2949307109
- Cited by
- 209
- References
- 0
- FWCI
- 4.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrochemical denitrification of highly contaminated actual nitrate wastewater by Ti/RuO2 anode and iron cathode. https://app.cochat.ai/papers/10.1016/j.cej.2019.122065
- The paper
- Chauhan, R., & Srivastava, V. C. (2020). Electrochemical denitrification of highly contaminated actual nitrate wastewater by Ti/RuO2 anode and iron cathode. Chemical Engineering Journal. https://doi.org/10.1016/j.cej.2019.122065
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.