Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 206

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Comparison of UVC and UVC/persulfate processes for tetracycline removal in water

Xu, Mengyuan, Deng, Jing, Cai, Anhong, Ma, Xiaoyan, Li, Jun, Li, Qingsong, Li, Xueyan · 2020 · Chemical Engineering Journal

Abstract

The comparative study on the elimination of tetracycline (TC) utilizing UVC and UVC/PS processes was systematically conducted. The TC degradation via UVC irradiation and UVC/PS treatment well fitted pseudo first-order kinetics. Hydroxyl radicals ( OH) and sulfate radicals (SO4− ) were identified as the primary reactive species in UVC/PS process. Based on competition kinetic method, the second-order reaction rate constants of TC reacting with OH and SO4− were calculated as 4.6 × 109 and 2.2 × 109 M−1 s−1, respectively. The contributions of UVC photolysis, OH and SO4− to TC degradation were calculated as 5.91%, 61.97% and 28.11% at pH 7.0, respectively. The TC degradation in UVC and UVC/PS process was highly pH-dependent and enhanced with the increase of solution pH. Water matrix constituents played the multiple roles in TC degradation, including radical sensitizer, radical quencher and light absorber. Natural organic matters, CO32– and HCO3– enhanced the degradation during UVC photolysis, whereas the opposite phenomenon occurred in UVC/PS process. Cl− presented the inhibitory effect, while TC degradation can be accelerated by NO3– both in UVC and UVC/PS processes. The TC degradation in UVC/PS process can be classified into the hydroxylation, demethylation, decarbonylation, photocyclinzation, dehydration and cleavage of C N bond. After UVC and UVC/PS pretreatment, the decreased formation of dichloroacetic acid and trichloroacetic acid and the increased production of trichloromethane have been found. The TC removal was evaluated in terms of electrical energy per order, and its value can be considerably reduced via the combination of UVC and PS. Except for ultrapure water, the removal of TC from real waters by UVC/PS treatment could also be desirable.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.cej.2019.123320

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 206

Metadata

Authors
Xu, M., Deng, J., Cai, A., Ma, X., Li, J., Li, Q., & Li, X.
Venue
Chemical Engineering Journal
Publisher
Elsevier BV
Published
2020-03
Volume
384
Pages
123320
ISSN
1385-8947 (ISSN-L)
OpenAlex
W2987280504
Cited by
206
References
4
FWCI
8.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.