The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Low-temperature tolerant strain sensors based on triple crosslinked organohydrogels with ultrastretchability
Abstract
Abstract Flexible electronic sensors based on conductive hydrogels have received extensive attention in the field of smart wearable electronics. However, the existing hydrogels usually cannot meet the necessary requirements due to their relatively narrow strain range, and low stability, especially at subzero temperatures. In this study, a xanthan gum-Fe3+/polyacrylamide-glycerol (XG-Fe3+/PAAm-Gl) organohydrogel was prepared via the polymerization in situ and solvent-exchange method. XG was initially used to prepare organohydrogels-based sensors with multiple interactions, including covalent cross-linking interaction, ionic coordination interaction and hydrogen bonds. The prepared organohydrogel possesses excellent mechanical properties, such as, ultrastretchability (~1769%) and high strength (~1.5 MPa). In addition, a water-glycerol binary solvent endows the organohydrogel with excellent long-term anti-drying and anti-freezing capabilities, and it can maintain excellent stretchability (>500%), good conductivity and transparency even at −40 °C. A simple biosensor was fabricated using the XG-Fe3+/PAAm-Gl organohydrogel and was used to monitor the detection of human physiological motions, showing remarkable sensitivity and a wide strain range (5% to 500% strain) under a broad range of temperatures (−40 °C to 25 °C). The XG-Fe3+/PAAm-Gl organohydrogel is expected to meet the requirements of flexible sensors for adaption to many complicated environments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Soft Microfluidic Assemblies of Sensors, Circuits, and Radios for the Skin
Xu, S., Zhang, Y., Jia, L., Mathewson, K. E., Jang, K.-I., Kim, J., Fu, H., Huang, X., Chava, P., Wang, R., et al. (2014) · Science · doi:10.1126/science.1250169 · Cited by 1,199
Xia, S., Song, S., & Gao, G. (2018) · Chemical Engineering Journal · doi:10.1016/j.cej.2018.08.053 · Cited by 259
Skin sensors are the future of health care
Xu, S., Jayaraman, A., & Rogers, J. A. (2019) · Nature · doi:10.1038/d41586-019-02143-0 · Cited by 214
Cited by
Nanocomposite hydrogel-based strain and pressure sensors: a review
Sun, X., Yao, F., & Li, J. (2020) · Journal of Materials Chemistry A · doi:10.1039/d0ta06965e · Cited by 420
Self-citationZhang, Y., Zhang, R., & Tao, Y. (2023) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2023.121300 · Cited by 27
Metadata
- Authors
- Yu, Q., Qin, Z., Ji, F., Chen, S., Luo, S., Yao, M., Wu, X., Liu, W., Sun, X., Zhang, H., Zhao, Y., Yao, F., & Li, J.
- Venue
- Chemical Engineering Journal
- Publisher
- Elsevier BV
- Published
- 2021-01
- Volume
- 404
- Pages
- 126559
- ISSN
- 1385-8947 (ISSN-L)
- OpenAlex
- W3047426182
- Cited by
- 158
- References
- 3
- FWCI
- 7.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Low-temperature tolerant strain sensors based on triple crosslinked organohydrogels with ultrastretchability. https://app.cochat.ai/papers/10.1016/j.cej.2020.126559
- The paper
- Yu, Q., Qin, Z., Ji, F., Chen, S., Luo, S., Yao, M., Wu, X., Liu, W., Sun, X., Zhang, H., Zhao, Y., Yao, F., & Li, J. (2021). Low-temperature tolerant strain sensors based on triple crosslinked organohydrogels with ultrastretchability. Chemical Engineering Journal. https://doi.org/10.1016/j.cej.2020.126559
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.