CoChat

Enhanced adsorption performance for selected pharmaceutical compounds by sonicated Ti3C2TX MXene

Kim, Sewoon, Gholamirad, Farivash, Yu, Miao, Park, Chang Min, Jang, Am, Jang, Min, Taheri-Qazvini, Nadar, Yoon, Yeomin · 2021 · Chemical Engineering Journal
Cited by 194

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

This paper is aimed at evaluating the feasibility of selected pharmaceutical compounds’ adsorption on Ti3C2TX MXene (termed ‘MXene’ in this study) as the first attempt. For adsorption mechanism analysis, amitriptyline (AMT), verapamil, carbamazepine, 17 α-ethinyl estradiol, ibuprofen, and diclofenac were the selected pharmaceutical compounds and experiments were conducted in three different pH conditions (3.5, 7, and 10.5). Due to electrostatic attraction between negatively charged MXene and positively charged AMT, the adsorption capacity for AMT showed the highest value (58.7 mg/g) at pH 7. In addition, for enhanced adsorption performance, MXene sonicated at different frequencies (0, 28, and 580 kHz) was applied for AMT adsorption. The maximum adsorption capacity was observed in the following order: 28 kHz (214 mg/g) > 580 kHz (172 mg/g) > 0 kHz (138 mg/g). This is because cavitation bubbles by sonication can make well-dispersed MXene and more forming oxygenated functional groups on MXene. In particular, by generating larger cavitation bubbles, the highest performance was shown at lower frequencies. Furthermore, because there are a lot of ions in real aquatic environments, the effect of various ions on adsorption performance on pharmaceutical compounds was evaluated using sonicated MXene. Although background inorganics negatively affect adsorption performance, natural organic matter as background organics increased the adsorption performance. However, cetylpyridinium chloride (CPC), a major cationic surfactant of the pharmaceutical industry, had a negative effect on adsorption performance by exhibiting a competition effect between CPC and pharmaceutical compounds. Finally, a comparison between sonicated MXene and commercial powdered activated carbon and recyclability performances indicated that sonicated MXene could be an alternative adsorbent for pharmaceutical compounds removal due to its high adsorption capacity, selectivity, and reusability.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.cej.2020.126789

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 194

Metadata

Authors
Kim, S., Gholamirad, F., Yu, M., Park, C. M., Jang, A., Jang, M., Taheri-Qazvini, N., & Yoon, Y.
Venue
Chemical Engineering Journal
Publisher
Elsevier BV
Published
2021-02
Volume
406
Pages
126789
ISSN
1385-8947 (ISSN-L)
OpenAlex
W3082725352
Cited by
194
References
5
FWCI
8.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Enhanced adsorption performance for selected pharmaceutical compounds by sonicated Ti3C2TX MXene. https://app.cochat.ai/papers/10.1016/j.cej.2020.126789
The paper
Kim, S., Gholamirad, F., Yu, M., Park, C. M., Jang, A., Jang, M., Taheri-Qazvini, N., & Yoon, Y. (2021). Enhanced adsorption performance for selected pharmaceutical compounds by sonicated Ti3C2TX MXene. Chemical Engineering Journal. https://doi.org/10.1016/j.cej.2020.126789

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.