Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 344

The DOI matches its Crossref record; 83 of the 83 references it cites were found in a registry or an index.

Degradation of acetaminophen by activated peroxymonosulfate using Co(OH)2 hollow microsphere supported titanate nanotubes: Insights into sulfate radical production pathway through CoOH+ activation

Chen, Long, Ji, Haodong, Qi, Juanjuan, Huang, Taobo, Wang, Chong-Chen, Liu, Wen·2021·Chemical Engineering Journal

Abstract

Abstract Pharmaceuticals and personal care products (PPCPs) are of great concern due to their increasing health effects, so advanced treatment technologies for PPCPs removal are urgently needed. In this study, titanate nanotubes decorated Co(OH)2 hollow microsphere (CoM/TNTs) composites were synthesized by a two-step solvothermal method, and used to activate peroxymonosulfate (PMS) through heterogenous catalysis for acetaminophen (ACE) degradation in water. The optimum material (CoM/TNTs0.5) activated PMS system exhibited high ACE removal efficiency and quick kinetic, as 93.0% ACE was degraded even within 10 min. The two components in CoM/TNTs showed a synergetic effect on PMS activation for radicals production: Co(OH)+ from CoM was the primary active species to active PMS, while TNTs could offer abundant –OH groups for Co(OH)+ formation. Density functional theory (DFT) calculation further interpreted the mechanism of Co(OH)+ for PMS activation by means of reaction potential energy surface (PES) analysis. Both the scavenger quenching tests and electron paramagnetic resonance analysis revealed that the sulfate radical (SO4-·) played a dominant role in ACE degradation. Moreover, DFT calculation also suggested that the ACE atoms with high Fukui index (f -) represented the active sites for electrophilic attack by SO4-·. The toxicity analysis based on quantitative structure-activity relationship (QSAR) verified the reduced toxicity of transformation products. Furthermore, CoM/TNTs also had good reusability and stability over five cycles. This work provides deep insights into the reaction mechanisms of radical production and organics attack in cobalt-based PMS activation system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.cej.2020.126877

Cites

83 of 83 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

1 retracted

Show all 83 references

Cited by

Metadata

Authors
Chen, L., Ji, H., Qi, J., Huang, T., Wang, C.-C., & Liu, W.
Venue
Chemical Engineering Journal
Publisher
Elsevier BV
Published
2021-02
Volume
406
Pages
126877
ISSN
1385-8947 (ISSN-L)
OpenAlex
W3081677079
Cited by
344
References
83
FWCI
11.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Degradation of acetaminophen by activated peroxymonosulfate using Co(OH)2 hollow microsphere supported titanate nanotubes: Insights into sulfate radical production pathway through CoOH+ activation. https://app.cochat.ai/papers/10.1016/j.cej.2020.126877
The paper
Chen, L., Ji, H., Qi, J., Huang, T., Wang, C.-C., & Liu, W. (2021). Degradation of acetaminophen by activated peroxymonosulfate using Co(OH)2 hollow microsphere supported titanate nanotubes: Insights into sulfate radical production pathway through CoOH+ activation. Chemical Engineering Journal. https://doi.org/10.1016/j.cej.2020.126877

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.