The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Activation of peroxodisulfate and peroxymonosulfate by ultrasound with different frequencies: Impact on ibuprofen removal efficient, cost estimation and energy analysis
Abstract
Abstract The purpose of this study was to investigate the advanced oxidation processes (AOPs) utilizing peroxodisulfate (PDS), peroxymonosulfate (PMS), and hydrogen peroxide (H2O2), at different ultrasonic frequencies, by comparing the degradation efficiency for ibuprofen (IBP) on a bench scale. At different ultrasound(US) frequencies under the same calorimetric energies, the activation efficiencies of PDS, PMS, US-PDS, and US-PMS as well as the influence of operating parameters on US-H2O2 processing efficiency were also investigated. As a result, the activation efficiency of PDS and PMS as well as the IBP kinetic constant were determined to be the largest at the frequency of 1000 kHz. In addition, the activation effect of PDS was found to be more effective than that of PMS when all ultrasonic frequencies were 1000 kHz. In addition, when the ultrasonic frequency was 1000 kHz, the values of IBP kinetic constants were observed in the following order: US1000kHz-PDS>US1000kHz-PMS>US1000kHz-H2O2>US1000kHz systems. In addition, as the pH increased during IBP decomposition, the value of the IBP reaction rate constant decreased, while the activation energies for IBP decomposition were 18.84, 15.40, 16.34 and 18.61 kJ mol-1, respectively. Electrical energy per order(EEO) analysis showed that US1000kHz-PDS exhibited the smallest EEO (263.5 kWh m-3), and the cost was 41.8 $m-3. It is believed that the activation of PDS, PMS, and H2O2 using ultrasonic waves will contribute to the treatment of organic matter decomposition using HO● and SO4●--based AOPs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wang, J., & Wang, S. (2018) · Chemical Engineering Journal · doi:10.1016/j.cej.2017.11.059 · Cited by 4,087
Cited by
Yan, Y., Wei, Z., Duan, X., Long, M., Spinney, R., Dionysiou, D. D., Xiao, R., & Alvarez, P. J. J. (2023) · Environmental Science & Technology · doi:10.1021/acs.est.3c05153 · Cited by 726
Abdul, L., Si, X., Sun, K., & Si, Y. (2021) · Journal of Environmental Chemical Engineering · doi:10.1016/j.jece.2021.105419 · Cited by 52
Metadata
- Authors
- Lee, Y., Lee, S., Cui, M., Ren, Y., Park, B., Ma, J., Han, Z., & Khim, J.
- Venue
- Chemical Engineering Journal
- Publisher
- Elsevier BV
- Published
- 2021-06
- Volume
- 413
- Pages
- 127487
- ISSN
- 1385-8947 (ISSN-L)
- OpenAlex
- W3097347296
- Cited by
- 222
- References
- 1
- FWCI
- 7.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Activation of peroxodisulfate and peroxymonosulfate by ultrasound with different frequencies: Impact on ibuprofen removal efficient, cost estimation and energy analysis. https://app.cochat.ai/papers/10.1016/j.cej.2020.127487
- The paper
- Lee, Y., Lee, S., Cui, M., Ren, Y., Park, B., Ma, J., Han, Z., & Khim, J. (2021). Activation of peroxodisulfate and peroxymonosulfate by ultrasound with different frequencies: Impact on ibuprofen removal efficient, cost estimation and energy analysis. Chemical Engineering Journal. https://doi.org/10.1016/j.cej.2020.127487
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.