The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Functional and Molecular Characterization of Mechanoinsensitive “Silent” Nociceptors
Open accessAbstract
Mechanical and thermal hyperalgesia (pain hypersensitivity) are cardinal signs of inflammation. Although the mechanism underlying thermal hyperalgesia is well understood, the cellular and molecular basis of mechanical hyperalgesia is poorly described. Here, we have identified a subset of peptidergic C-fiber nociceptors that are insensitive to noxious mechanical stimuli under normal conditions but become sensitized to such stimuli when exposed to the inflammatory mediator nerve growth factor (NGF). Strikingly, NGF did not affect mechanosensitivity of other nociceptors. We show that these mechanoinsensitive "silent" nociceptors are characterized by the expression of the nicotinic acetylcholine receptor subunit alpha-3 (CHRNA3) and that the mechanically gated ion channel PIEZO2 mediates NGF-induced mechanosensitivity in these neurons. Retrograde tracing revealed that CHRNA3 + nociceptors account for ∼50% of all peptidergic nociceptive afferents innervating visceral organs and deep somatic tissues. Hence, our data suggest that NGF-induced "un-silencing" of CHRNA3 + nociceptors significantly contributes to the development of mechanical hyperalgesia during inflammation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Piezo1 and Piezo2 Are Essential Components of Distinct Mechanically Activated Cation Channels
Coste, B., Mathur, J., Schmidt, M., Earley, T. J., Ranade, S., Petrus, M. J., Dubin, A. E., & Patapoutian, A. (2010) · Science · doi:10.1126/science.1193270 · Cited by 3,316 · cited 7×
“However, PIEZO2 is expressed in almost 50% of all sensory neurons (Ranade et al., 2014), some of which express the heat-gated ion channel TRPV1 (Coste et al., 2010), suggesting that PIEZO2 is also present in some nociceptors.”
BackgroundResultInfluentialPeripheral contributions to visceral hyperalgesia.
Gebhart, G. (1999) · Canadian Journal of Gastroenterology and Hepatology · doi:10.1155/1999/730765 · Cited by 57
Cited by
Spatial transcriptomics of dorsal root ganglia identifies molecular signatures of human nociceptors
Tavares-Ferreira, D., Shiers, S., Ray, P. R., Wangzhou, A., Jeevakumar, V., Sankaranarayanan, I., Cervantes, A. M., Reese, J. C., Chamessian, A., Copits, B. A., et al. (2022) · Science Translational Medicine · doi:10.1126/scitranslmed.abj8186 · Cited by 451
A mechanism for the activation of the mechanosensitive Piezo1 channel by the small molecule Yoda1
Botello-Smith, W. M., Jiang, W., Zhang, H., Ozkan, A. D., Lin, Y.-C., Pham, C. N., Lacroix, J. J., & Luo, Y. (2019) · Nature Communications · doi:10.1038/s41467-019-12501-1 · Cited by 274
Single-cell RNAseq reveals seven classes of colonic sensory neuron
Hockley, J. R. F., Taylor, T. S., Callejo, G., Wilbrey, A. L., Gutteridge, A., Bach, K., Winchester, W. J., Bulmer, D. C., McMurray, G., & Smith, E. S. J. (2019) · Gut · doi:10.1136/gutjnl-2017-315631 · Cited by 256
Self-citationXie, Z., Feng, J., Hibberd, T. J., Chen, B. N., Zhao, Y., Zang, K., Hu, X., Yang, X., Chen, L., Brookes, S. J., et al. (2023) · Neuron · doi:10.1016/j.neuron.2022.11.015 · Cited by 84
Buijs, R. M., Guzmán Ruiz, M. A., Méndez Hernández, R., & Rodríguez Cortés, B. (2019) · Autonomic Neuroscience · doi:10.1016/j.autneu.2019.02.001 · Cited by 63
Metadata
- Authors
- Prato, V., Taberner, F. J., Hockley, J. R. F., Callejo, G., Arcourt, A., Tazir, B., Hammer, L., Schad, P., Heppenstall, P. A., Smith, E. S., & Lechner, S. G.
- Venue
- Cell Reports
- Publisher
- Elsevier BV
- Published
- 2017-12
- Volume
- 21
- Issue
- 11
- Pages
- 3102-3115
- ISSN
- 2211-1247 (ISSN-L)
- OpenAlex
- W2774300852
- Cited by
- 182
- References
- 2
- FWCI
- 9.79
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.