Inactivation Kinetics and Mechanical Gating of Piezo1 Ion Channels Depend on Subdomains within the Cap
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Piezo1 ion channels are activated by mechanical stimuli and mediate the sensing of blood flow. Although cryo-electron microscopy (cryo-EM) structures have revealed the overall architecture of Piezo1, the precise domains involved in activation and subsequent inactivation have remained elusive. Here, we perform a targeted chimeric screen between Piezo1 and the closely related isoform Piezo2 and use electrophysiology to characterize their inactivation kinetics during mechanical stimulation. We identify three small subdomains within the extracellular cap that individually can confer the distinct kinetics of inactivation of Piezo2 onto Piezo1. We further show by cysteine crosslinking that conformational flexibility of these subdomains is required for mechanical activation to occur and that electrostatic interactions functionally couple the cap to the extensive blades, which have been proposed to function as sensors of membrane curvature and tension. This study provides a demonstration of internal gating motions involved in mechanotransduction by Piezo1.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Piezo1 and Piezo2 Are Essential Components of Distinct Mechanically Activated Cation Channels
Coste, B., Mathur, J., Schmidt, M., Earley, T. J., Ranade, S., Petrus, M. J., Dubin, A. E., & Patapoutian, A. (2010) · Science · doi:10.1126/science.1193270 · Cited by 3,316 · cited 18×
“Mouse Piezo2 was synthesized to be codon optimized for expression in human cells by Genewiz and ligated into pcDNA3.”
InfluentialStretch-activated ion channel Piezo1 directs lineage choice in human neural stem cells
Pathak, M. M., Nourse, J. L., Tran, T., Hwe, J., Arulmoli, J., Le, D. T. T., Bernardis, E., Flanagan, L. A., & Tombola, F. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1409802111 · Cited by 657
Structure of the mechanically activated ion channel Piezo1
Saotome, K., Murthy, S. E., Kefauver, J. M., Whitwam, T., Patapoutian, A., & Ward, A. B. (2018) · Nature · doi:10.1038/nature25453 · Cited by 649 · cited 6×
“…the narrowest constriction; in all existing structures, this constriction site is too narrow to allow permeation of cations, and thus, the structures are interpreted to be in closed states (Saotome et al., 2018; Taberner et al., 2019; Wang et al., 2019; Zhao et al., 2018; Zheng et al., 2019a).”
InfluentialStructure and mechanogating mechanism of the Piezo1 channel
Zhao, Q., Zhou, H., Chi, S., Wang, Y., Wang, J., Geng, J., Wu, K., Liu, W., Zhang, T., Dong, M.-Q., et al. (2018) · Nature · doi:10.1038/nature25743 · Cited by 628 · cited 6×
“…the narrowest constriction; in all existing structures, this constriction site is too narrow to allow permeation of cations, and thus, the structures are interpreted to be in closed states (Saotome et al., 2018; Taberner et al., 2019; Wang et al., 2019; Zhao et al., 2018; Zheng et al., 2019a).”
InfluentialEndothelial cation channel PIEZO1 controls blood pressure by mediating flow-induced ATP release
Wang, S., Chennupati, R., Kaur, H., Iring, A., Wettschureck, N., & Offermanns, S. (2016) · Journal of Clinical Investigation · doi:10.1172/jci87343 · Cited by 616 · cited 1×
“…and vascular flow in order to regulate blood pressure, arterial remodeling, and blood cell volume (Cahalan et al., 2015; Retailleau et al., 2015; Wang et al., 2016; Zeng et al., 2018), as well as in neural stem cells, where it senses cellular traction forces and local environment to control…”
Structure-based membrane dome mechanism for Piezo mechanosensitivity
Guo, Y. R., & MacKinnon, R. (2017) · eLife · doi:10.7554/elife.33660 · Cited by 446 · cited 7×
“…data demonstrate that both residues can crosslink and further suggest that stabilizing this intersubunit interaction promotes a non-conducting conformation, which is consistent with the closed pore observed in the Piezo1 structure in which this salt bridge is prominent (Guo and MacKinnon, 2017).”
InfluentialForce-induced conformational changes in PIEZO1
Lin, Y.-C., Guo, Y. R., Miyagi, A., Levring, J., MacKinnon, R., & Scheuring, S. (2019) · Nature · doi:10.1038/s41586-019-1499-2 · Cited by 433
Cited by
Discoveries in structure and physiology of mechanically activated ion channels
Kefauver, J. M., Ward, A. B., & Patapoutian, A. (2020) · Nature · doi:10.1038/s41586-020-2933-1 · Cited by 604
Structure deformation and curvature sensing of PIEZO1 in lipid membranes
Yang, X., Lin, C., Chen, X., Li, S., Li, X., & Xiao, B. (2022) · Nature · doi:10.1038/s41586-022-04574-8 · Cited by 305
Mechanisms of mechanotransduction and physiological roles of PIEZO channels
Xiao, B. (2024) · Nature Reviews Molecular Cell Biology · doi:10.1038/s41580-024-00773-5 · Cited by 287
Tang, H., Zeng, R., He, E., Zhang, I., Ding, C., & Zhang, A. (2022) · Journal of Medicinal Chemistry · doi:10.1021/acs.jmedchem.2c00085 · Cited by 120
Jojoa-Cruz, S., Burendei, B., Lee, W.-H., & Ward, A. B. (2024) · Structure · doi:10.1016/j.str.2023.11.009 · Cited by 20
Metadata
- Authors
- Lewis, A. H., & Grandl, J.
- Venue
- Cell Reports
- Publisher
- Elsevier BV
- Published
- 2020-01
- Volume
- 30
- Issue
- 3
- Pages
- 870-880.e2
- ISSN
- 2211-1247 (ISSN-L)
- OpenAlex
- W3001537456
- Cited by
- 82
- References
- 7
- FWCI
- 5.15
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.