Abstract Accelerated laboratory tests on resistance of concrete exposed to sulfate attack have generally been conducted in high-concentration sulfate solutions or under drastic drying-wetting cycle conditions. However, these accelerated regimes radically alter the nature of sulfate attack mechanisms on concrete under real field exposure situation. To obtain reliable information on the long-term behaviors of concrete under real field conditions, the behaviors of concrete samples under three different exposure regimes, i.e., continuous full immersion, full immersion with general use drying-wetting cycles and full immersion with natural drying-wetting cycles, were investigated in this research. Three different concentrations of sulfate sodium solutions, i.e., 0% water for control, 2.1% for field-like condition and 15% for high-concentration condition, were considered. Physical and mechanical properties, such as mass, expansion, permeability and compressive strength, were tested at regular time intervals during the whole exposure period to describe the associated evolution laws. Microanalysis was also carried out to identify the underlying mechanisms. Results from this study showed that the exposure regime of full immersion in 2.1% sulfate sodium solutions subjected to natural drying-wetting cycles can well reproduce the field exposure condition of concrete under certain sulfate-rich environments. Both concentration and exposure type affect the nature of sulfate attack mechanism on concrete, along with the evolution of physical and mechanical properties. A three-stage evolution model, consisting of the enhancement stage, the incubation stage and the degeneration stage, was observed in the property evolution of concrete samples under the field-like exposure condition. Meanwhile, a distinct coupling physicochemical damage on concrete samples was detected when subjected to drying-wetting cycle exposure. In addition, the effects of water-to-binder ratio and binder type were duly studied.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.cemconres.2018.11.017

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

1 retracted

Show all 20 references

Cited by

See all 208

Metadata

Authors
Zhang, Z., Jin, X., & Luo, W.
Venue
Cement and Concrete Research
Publisher
Elsevier BV
Published
2019-02
Volume
116
Pages
217-230
ISSN
0008-8846 (ISSN-L)
OpenAlex
W2905447158
Cited by
208
References
20
FWCI
12.57
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Long-term behaviors of concrete under low-concentration sulfate attack subjected to natural variation of environmental climate conditions. https://app.cochat.ai/papers/10.1016/j.cemconres.2018.11.017
The paper
Zhang, Z., Jin, X., & Luo, W. (2019). Long-term behaviors of concrete under low-concentration sulfate attack subjected to natural variation of environmental climate conditions. Cement and Concrete Research. https://doi.org/10.1016/j.cemconres.2018.11.017

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.