CoChat

Validation of EncephalApp, Smartphone-Based Stroop Test, for the Diagnosis of Covert Hepatic Encephalopathy

Open access
Bajaj, Jasmohan S., Heuman, Douglas M., Sterling, Richard K., Sanyal, Arun J., Siddiqui, Muhammad, Matherly, Scott, Luketic, Velimir, Stravitz, R. Todd, Fuchs, Michael, Thacker, Leroy R., Gilles, HoChong, White, Melanie B., Unser, Ariel, Hovermale, James, Gavis, Edith, Noble, Nicole A., Wade, James B. · 2015 · Clinical Gastroenterology and Hepatology
Cited by 190

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Abstract

Background & Aims Detection of covert hepatic encephalopathy (CHE) is difficult but point of care testing could increase rates of diagnosis. We aimed to validate the ability of the smartphone app EncephalApp, a streamlined version of Stroop App, to detect CHE. We evaluated face validity, test–retest reliability, and external validity. Methods Patients with cirrhosis (n=167; 38% with overt HE [OHE]; mean age, 55 years; mean model for end-stage liver disease score, 12) and controls (n=114) were each given a paper and pencil cognitive battery (standard) along with EncephalApp. EncephalApp has Off and On states; results measured were: OffTime, OnTime, OffTime+OnTime, and number of runs required to complete 5 off and on runs. Thirty-six patients with cirrhosis underwent driving simulation tests, and EncephalApp results were correlated with results. Test–retest reliability was analyzed in a subgroup of patients. The test was performed before and after transjugular intra-hepatic portosystemic shunt placement, before and after correction for hyponatremia, to determine external validity. Results All patients with cirrhosis performed worse on paper and pencil and EncephalApp tests than controls. Patients with cirrhosis and OHE performed worse than those without OHE. Age-dependent EncephalApp cut-offs (younger or older than 45 years) were set. An OffTime+OnTime value of >190 seconds identified all patients with CHE with an area under the receiver operator characteristic (AUROC) value of 0.91; the AUROC value was 0.88 for diagnosis of CHE in those without OHE. EncephalApp times correlated with crashes and illegal turns in driving simulation tests. Test–retest reliability was high (intra-class coefficient, 0.83) among 30 patients retested 1–3 months apart. OffTime+OnTime increased significantly (206 vs 255, P=.007) among 10 patients retested 33±7 days after transjugular intra-hepatic portosystemic shunt placement. OffTime+OnTime decreased significantly (242 vs 225, P=.03) in 7 patients tested before and after correction for hyponatremia (126±3 to 132±4 meq/L, P=.01), 10±5 days apart. Conclusions A smartphone app called EncephalApp has good face validity, test–retest reliability, and external validity for the diagnosis of CHE.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.cgh.2014.05.011

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 190

Metadata

Authors
Bajaj, J. S., Heuman, D. M., Sterling, R. K., Sanyal, A. J., Siddiqui, M., Matherly, S., Luketic, V., Stravitz, R. T., Fuchs, M., Thacker, L. R., Gilles, H., White, M. B., Unser, A., Hovermale, J., Gavis, E., Noble, N. A., & Wade, J. B.
Venue
Clinical Gastroenterology and Hepatology
Publisher
Elsevier BV
Published
2015-10
Volume
13
Issue
10
Pages
1828-1835.e1
ISSN
1542-3565 (ISSN-L)
OpenAlex
W2150822431
Cited by
190
References
24
FWCI
4.80
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validation of EncephalApp, Smartphone-Based Stroop Test, for the Diagnosis of Covert Hepatic Encephalopathy. https://app.cochat.ai/papers/10.1016/j.cgh.2014.05.011
The paper
Bajaj, J. S., Heuman, D. M., Sterling, R. K., Sanyal, A. J., Siddiqui, M., Matherly, S., Luketic, V., Stravitz, R. T., Fuchs, M., Thacker, L. R., Gilles, H., White, M. B., Unser, A., Hovermale, J., Gavis, E., Noble, N. A., & Wade, J. B. (2015). Validation of EncephalApp, Smartphone-Based Stroop Test, for the Diagnosis of Covert Hepatic Encephalopathy. Clinical Gastroenterology and Hepatology. https://doi.org/10.1016/j.cgh.2014.05.011

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.