Diagnostic Yield of One-Time Colonoscopy vs One-Time Flexible Sigmoidoscopy vs Multiple Rounds of Mailed Fecal Immunohistochemical Tests in Colorectal Cancer Screening
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
BACKGROUND & AIMS We compared the diagnostic yields of colonoscopy, flexible sigmoidoscopy, and fecal immunochemical tests (FITs) in colorectal cancer (CRC) screening. METHODS A total of 30,007 asymptomatic persons, 50-74 years old, were invited for CRC screening in the Netherlands. Participants were assigned to groups that received 4 rounds of FIT (mailed to 15,046 participants), once-only flexible sigmoidoscopy (n=8407), or once-only colonoscopy (n=6600). Patients with positive results from the FIT (≥10 μg Hb/g feces) were referred for colonoscopies. Patients who underwent flexible sigmoidoscopy were referred for colonoscopy if they had a polyp of ≥10 mm; adenoma with ≥25% villous histology or high-grade dysplasia; sessile serrated adenoma; ≥3 adenomas; ≥20 hyperplastic polyps; or invasive CRC. The primary outcome was number of advanced neoplasias detected (diagnostic yield) by each test. Secondary outcomes were number of colonoscopies needed to detect advanced neoplasia and number of interval CRCs found during each primary screening test. Patients with interval CRCs (detected between a negative result from a screening colonoscopy and next scheduled colonoscopy) were found through linkage with Netherlands Cancer Registry. Advanced neoplasias were defined as CRC, adenomas ≥ 10 mm, adenomas with high-grade dysplasia, or adenomas with a villous component of at least 25%. RESULTS The cumulative participation rate was significantly higher for FIT screening (77%) than for flexible sigmoidoscopy (31%; P<.001) or colonoscopy (24%; P<.001). The percentage of colonoscopies among invitees was higher for colonoscopy (24%) compared to FIT (13%; P<.001) or flexible sigmoidoscopy (3%; P<.001). In the intention to screen analysis, the cumulative diagnostic yield of advanced neoplasia was higher with FIT screening (4.5%; 95% CI 4.2-4.9) than with colonoscopy (2.2%; 95% CI, 1.8-2.6) or flexible sigmoidoscopy (2.3%; 95% CI, 2.0-2.7). In the as-screened analysis, the cumulative yield of advanced neoplasia was higher for endoscopic screening with colonoscopy (9.1%; 95% CI, 7.7-10.7) or flexible sigmoidoscopy (7.4%; 95% CI, 6.5-8.5) than with the FIT (6.1%; 95% CI, 5.7-6.6). All 3 screening strategies detected a similar proportion of patients with CRC. Follow-up times differed for each test (median 8.3 years for FIT and flexible sigmoidoscopy and 5.8 years for colonoscopy). Proportions of patients that developed interval CRC were 0.13% for persons with a negative result from the FIT, 0.09% for persons with a negative result from flexible sigmoidoscopy, and 0.01% for persons with a negative result from colonoscopy. CONCLUSIONS Mailed multiple-round FITs detect significantly more advanced neoplasias, on a population level, compared with once-only flexible sigmoidoscopy or colonoscopy screening. Significantly fewer colonoscopies are required by individuals screened by multiple FITs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Colorectal cancer screening: a global overview of existing programmes
Schreuders, E. H., Ruco, A., Rabeneck, L., Schoen, R. E., Sung, J. J. Y., Young, G. P., & Kuipers, E. J. (2015) · Gut · doi:10.1136/gutjnl-2014-309086 · Cited by 1,328
Self-citationZorzi, M., Fedeli, U., Schievano, E., Bovo, E., Guzzinati, S., Baracco, S., Fedato, C., Saugo, M., & Dei Tos, A. P. (2015) · Gut · doi:10.1136/gutjnl-2014-307508 · Cited by 302
Cited by
Lin, J. S., Bowles, E. J. A., Williams, S. B., & Morrison, C. C. (2017) · JAMA · doi:10.1001/jama.2017.0562 · Cited by 1,082
Lin, J. S., Perdue, L. A., Henrikson, N. B., Bean, S. I., & Blasi, P. R. (2021) · JAMA · doi:10.1001/jama.2021.4417 · Cited by 650
Optimizing the quality of colorectal cancer screening worldwide
Kaminski, M. F., Robertson, D. J., Senore, C., & Rex, D. K. (2020) · Gastroenterology · doi:10.1053/j.gastro.2019.11.026 · Cited by 171
Optimal Strategies for Colorectal Cancer Screening
Jain, S., Maque, J., Galoosian, A., Osuna-Garcia, A., & May, F. P. (2022) · Current Treatment Options in Oncology · doi:10.1007/s11864-022-00962-4 · Cited by 110
Metadata
- Authors
- Grobbee, E. J., van der Vlugt, M., van Vuuren, A. J., Stroobants, A. K., Mallant-Hent, R. C., Lansdorp-Vogelaar, I., Bossuyt, P. M. M., Kuipers, E. J., Dekker, E., & Spaander, M. C. W.
- Venue
- Clinical Gastroenterology and Hepatology
- Publisher
- Elsevier BV
- Published
- 2020-03
- Volume
- 18
- Issue
- 3
- Pages
- 667-675.e1
- ISSN
- 1542-3565 (ISSN-L)
- OpenAlex
- W2967621287
- Cited by
- 53
- References
- 2
- FWCI
- 2.27
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.