Cost effectiveness of different strategies for detecting cirrhosis in patients with nonalcoholic fatty liver disease based on United States health care system
Open accessAbstract
Background & aims Several strategies are available for detecting cirrhosis in patients with nonalcoholic fatty liver disease (NAFLD), but their cost effectiveness is not clear. We developed a decision model to quantify the accuracy and costs of 9 single or combination strategies, including 3 noninvasive tests (fibrosis-4 [FIB-4], vibration-controlled transient elastography [VCTE], and magnetic resonance elastography [MRE]) and liver biopsy, for the detection of cirrhosis in patients with NAFLD.Methods Data on the diagnostic accuracy, costs, adverse events, and cirrhosis outcomes over a 5-year period were obtained from publications. The diagnostic accuracy, per-patient cost per correct diagnosis of cirrhosis, and incremental cost-effectiveness ratios (ICERs) were calculated for each strategy for base cirrhosis prevalence values of 0.27%, 2%, and 4%.Results The combination of the FIB-4 and VCTE identified patients with cirrhosis in NAFLD populations with a 0.27%, 2%, and 4% prevalence of cirrhosis with the lowest cost per person ($401, $690, and $1024, respectively) and highest diagnostic accuracy (89.3%, 88.5%, and 87.5% respectively). The combination of FIB-4 and MRE ranked second in cost per person ($491, $781, and $1114, respectively) and diagnostic accuracy (92.4%, 91.6%, 90.6%, respectively). Compared with the combination of FIB-4 and VCTE (least costly), the ICERs were lower for the combination of FIB-4 and MRE ($2864, $2918, and $2921) than the combination of FIB-4 and liver biopsy ($4454, $5156, and $5956) at the cirrhosis prevalence values tested. When the goal was to avoid liver biopsy, FIB-4 + VCTE and FIB-4 + MRE had similar diagnostic accuracies, ranging from 87.5% to 89.3% and 90.6% to 92.4% for a cirrhosis diagnosis, respectively, although FIB-4 + MRE had a slightly higher cost.Conclusions In our cost-effectiveness analysis based on the US health care system, we found that results from FIB-4, followed by either VCTE, MRE, or liver biopsy, detect cirrhosis in patients with NAFLD with a high level of accuracy and low cost. Compared with FIB-4 + VCTE, which was the least costly strategy, FIB-4 + MRE had a lower ICER than FIB-4 + LB.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
There have been positive cost-effectiveness studies on MASLD or fibrosis screening in the general population and among individuals diagnosed with SLD, metabolic syndrome, and T2D.
“There have been positive cost-effectiveness studies on MASLD or fi brosis screening in the general population, 129 and among individuals diagnosed with SLD, 130 metabolic syndrome, 131 and T2D.”
From EASL-EASD-EASO Clinical Practice Guidelines on the management of metabolic dysfunction-associated steatotic liver disease (MASLD). (2024) · cites this paper as [130]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 34 · Cited by 75
- Authors
- Vilar-Gomez, E., Lou, Z., Kong, N., Vuppalanchi, R., Imperiale, T. F., & Chalasani, N.
- Affiliations
- Purdue University West Lafayette (US)
- Indiana University School of Medicine (US)
- Regenstrief Institute (US)
- Indiana University Indianapolis (US)
- Corresponding author
- Chalasani, Naga
- Venue
- Clinical Gastroenterology and Hepatology
- Publisher
- Elsevier BV
- Published
- 2020-09
- Volume
- 18
- Issue
- 10
- Pages
- 2305-2314.e12
- ISSN
- 1542-3565 (ISSN-L)
- OpenAlex
- W3015766055
- Cited by
- 75
- References
- 34
- Citations by year
- 2026: 9 · 2025: 16 · 2024: 12 · 2023: 11 · 2022: 15 · 2021: 7 · 2020: 5
- FWCI
- 6.80
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Locations
- Clinical Gastroenterology and Hepatology (publishedVersion)
- PubMed (publishedVersion)
- Purdue University Indianapolis (Indiana University) (submittedVersion)
- IUScholarWorks (Indiana University) (submittedVersion)
- Funders
- Genentech
- AbbVie
- Topics
- Health Sciences › Medicine › Epidemiology › Liver Disease Diagnosis and Treatment
- Social Sciences › Economics, Econometrics and Finance › Economics and Econometrics › Health Systems, Economic Evaluations, Quality of Life
- Health Sciences › Medicine › Hepatology › Liver Disease and Transplantation
- Keywords
- non-alcoholic fatty liver disease, cost-effectiveness, FIB-4, vibration-controlled transient elastography, magnetic resonance elastography, liver biopsy, incremental cost-effectiveness ratio, decision models, United States health care system, mortality risk stratification, cirrhosis complications
- MeSH terms
- Biopsy, Cost-Benefit Analysis, Delivery of Health Care, Fibrosis, Humans, Liver, Liver Cirrhosis, United States, Elasticity Imaging Techniques, Non-alcoholic Fatty Liver Disease
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review