CoChat

Determination of Fe3+/ΣFe of XANES basaltic glass standards by Mössbauer spectroscopy and its application to the oxidation state of iron in MORB

Open access
Zhang, Hongluo L., Cottrell, Elizabeth, Solheid, Peat A., Kelley, Katherine A., Hirschmann, Marc M. · 2018 · Chemical Geology
Cited by 162

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

To improve the accuracy of X-ray absorption near-edge structure (XANES) calibrations for the Fe 3 + /ΣFe ratio in basaltic glasses, we reevaluated the Fe 3 + /ΣFe ratios of glasses used as standards by Cottrell et al. (2009), and available to the community (NMNH catalog #117393). Here we take into account the effect of recoilless fraction on the apparent Fe 3 + /ΣFe ratio measured from room temperature Mössbauer spectra in that original study. Recoilless fractions were determined from Mössbauer spectra collected from 40 to 320 K for one basaltic glass, AII_25, and from spectra acquired at 10 K for the 13 basaltic glass standards from the study of Cottrell et al. (2009). The recoilless fractions, f , of Fe 2 + and Fe 3 + in glass AII_25 were calculated from variable-temperature Mössbauer spectra by a relative method (RM), based on the temperature dependence of the absorption area ratios of Fe 3 + and Fe 2 + paramagnetic doublets. The resulting correction factor applicable to room temperature determinations ( C 293 , the ratio of recoilless fractions for Fe 3 + and Fe 2 + ) is 1.125 ± 0.068 (2σ). Comparison of the spectra at 10 K for the 13 basaltic glasses with those from 293 K suggests C 293 equal to 1.105 ± 0.015 (2σ). Although the 10 K estimate is more precise, the relative method determination is believed to be more accurate, as it does not depend on the assumption that recoilless fractions are equal at 10 K. Applying the effects of recoilless fraction to the relationship between Mössbauer-determined Fe 3 + /ΣFe ratios and revised average XANES pre-edge centroids for the 13 standard glasses allows regression of a new calibration of the relationship between the Fe XANES pre-edge centroid energy and the Fe 3 + /ΣFe ratio of silicate glass. We also update the calibration of Zhang et al. (2016) for andesites and present a more general calibration for mafic glasses including both basaltic and andesitic compositions. Recalculation of Fe 3 + /ΣFe ratios for the mid-ocean ridge basalt (MORB) glasses analyzed previously by XANES by Cottrell and Kelley (2011) results in an average Fe 3 + /ΣFe ratio for MORB of 0.143 ± 0.008 (1σ), taking into account only analytical precision, and 0.14 ± 0.01(1σ), taking into account uncertainty on the value of C 293 . This revised average is lower than the average of 0.16 ± 0.01 given by Cottrell and Kelley (2011). The revised average oxygen fugacity for MORB based on the database of Cottrell and Kelley (2011) is − 0.18 ± 0.16 log units less than the quartz-fayalite-magnetite buffer of Frost (1991) at 100 kPa (∆ QFM = − 0.18 ± 0.16).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.chemgeo.2018.01.006

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Metadata

Authors
Zhang, H. L., Cottrell, E., Solheid, P. A., Kelley, K. A., & Hirschmann, M. M.
Venue
Chemical Geology
Publisher
Elsevier BV
Published
2018-02
Volume
479
Pages
166-175
ISSN
0009-2541 (ISSN-L)
OpenAlex
W2781674151
Cited by
162
References
2
FWCI
14.86
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Determination of Fe3+/ΣFe of XANES basaltic glass standards by Mössbauer spectroscopy and its application to the oxidation state of iron in MORB. https://app.cochat.ai/papers/10.1016/j.chemgeo.2018.01.006
The paper
Zhang, H. L., Cottrell, E., Solheid, P. A., Kelley, K. A., & Hirschmann, M. M. (2018). Determination of Fe3+/ΣFe of XANES basaltic glass standards by Mössbauer spectroscopy and its application to the oxidation state of iron in MORB. Chemical Geology. https://doi.org/10.1016/j.chemgeo.2018.01.006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.