Baseline correction by improved iterative polynomial fitting with automatic threshold
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Barclay, V. J., Bonner, R. F., & Hamilton, I. P. (1997) · Analytical Chemistry · doi:10.1021/ac960638m · Cited by 253
Noise suppression and signal compression using the wavelet packet transform
Walczak, B., & Massart, D. L. (1997) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(96)00077-9 · Cited by 250
Baseline subtraction using robust local regression estimation
Ruckstuhl, A., Jacobson, M. P., Field, R. W., & Dodd, J. A. (2001) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/s0022-4073(00)00021-2 · Cited by 174
Improved Baseline Recognition and Modeling of FT NMR Spectra
Golotvin, S. S., & Williams, A. J. (2000) · Journal of Magnetic Resonance · doi:10.1006/jmre.2000.2121 · Cited by 95
Cited by
Baseline correction using adaptive iteratively reweighted penalized least squares
Zhang, Z.-M., Chen, S., & Liang, Y.-Z. (2010) · The Analyst · doi:10.1039/b922045c · Cited by 1,124
Baseline correction using asymmetrically reweighted penalized least squares smoothing
Baek, S.-J., Park, A., Ahn, Y.-J., & Choo, J. (2015) · The Analyst · doi:10.1039/c4an01061b · Cited by 477
Smolinska, A., Blanchet, L., Buydens, L. M. C., & Wijmenga, S. S. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.05.049 · Cited by 397
Optimal Choice of Baseline Correction for Multivariate Calibration of Spectra
Liland, K. H., Almøy, T., & Mevik, B.-H. (2010) · Applied Spectroscopy · doi:10.1366/000370210792434350 · Cited by 317
Chromatogram baseline estimation and denoising using sparsity (BEADS)
Ning, X., Selesnick, I. W., & Duval, L. (2014) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2014.09.014 · Cited by 208
“The low-pass part of the baseline may be modeled by regular functions, such as low-degree polynomials [33, 59] or (cubic) spline models [19, 23, 12], in conjunction with manual identification, polynomial fitting or iterative thresholding methods [21].”
MethodA review on spectral data preprocessing techniques for machine learning and quantitative analysis
Yan, C. (2025) · iScience · doi:10.1016/j.isci.2025.112759 · Cited by 193
“Exclude peaks ( w ti = 0) and fit baselines via adaptive weights (exponential in airPLS, sigmoid in IairPLS), balancing residuals and smoothness with penalty term λ (Equations 40, 41, and 42).”
Terahertz molecular resonance of cancer DNA
Cheon, H., Yang, H.-J., Lee, S.-H., Kim, Y. A., & Son, J.-H. (2016) · Scientific Reports · doi:10.1038/srep37103 · Cited by 182
Emwas, A.-H., Saccenti, E., Gao, X., McKay, R. T., dos Santos, V. A. P. M., Roy, R., & Wishart, D. S. (2018) · Metabolomics · doi:10.1007/s11306-018-1321-4 · Cited by 158
Pan, L., Zhang, P., Daengngam, C., Peng, S., & Chongcheawchamnan, M. (2022) · Journal of Raman Spectroscopy · doi:10.1002/jrs.6225 · Cited by 116
“introduced an improved iterative polynomial fitting with the automatic threshold for baseline correction [14].”
MethodPan, L., Pipitsunthonsan, P., Daengngam, C., Channumsin, S., Sreesawet, S., & Chongcheawchamnan, M. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3059849 · Cited by 29
“proposed an improved iterative polynomial fitting with automatic threshold for limit correction [20].”
Background
Metadata
- Authors
- Gan, F., Ruan, G., & Mo, J.
- Venue
- Chemometrics and Intelligent Laboratory Systems
- Publisher
- Elsevier BV
- Published
- 2006-05
- Volume
- 82
- Issue
- 1-2
- Pages
- 59-65
- ISSN
- 0169-7439 (ISSN-L)
- OpenAlex
- W2170903587
- Cited by
- 221
- References
- 4
- FWCI
- 1.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.