The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
4-Chlorophenol degradation using ultrasound/peroxymonosulfate/nanoscale zero valent iron: Reusability, identification of degradation intermediates and potential application for real wastewater
Abstract
In this study, nanoscale-zero valent iron (nZVI) was synthesized and its function was assessed in ultrasound (US)/peroxymonosulfate (PMS)/nZVI process to degrade 4-chlorphenol (4-CP). The influential operation parameters of US/PMS/nZVI were evaluated on 4-CP degradation. 95% of 4-CP was degraded during 30 min under the conditions of pH = 3.0, nZVI = 0.4 g/L, PMS = 1.25 mM, US power = 200 W. The rate constants of 4-CP degradation for US/PMS/nZVI, PMS/nZVI, US/PMS and US/nZVI were 0.1159, 0.03, 0.0134 and 0.0088 min-1 respectively. Simultaneous application of US and nZVI synergistically increased 4-CP degradation and PMS activation. nZVI was compared with Fe2+, Fe3+ and micro-ZVI and their results indicated high performance of nZVI compared to others. Reusability of nZVI was examined in four cycles. nZVI exhibited that reusability was acceptable in three runs. The results of effect of anions showed that phosphate had significant inhibitory effect on 4-CP degradation in US/PMS/nZVI process. The scavenging experiments indicated that hydroxyl radical had more contribution compared to sulfate radical. Intermediates of 4-CP degradation were identified including five aromatic compounds. Reaction pathway of 4-CP degradation was proposed. Finally, the performance of US/PMS/nZVI process was evaluated on real petrochemical wastewater. The results showed that US/PMS/nZVI can be a suitable pretreatment for biological treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sun, H., Kwan, C., Suvorova, A., Ang, H. M., Tadé, M. O., & Wang, S. (2014) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2014.02.012 · Cited by 509
Cited by
Giannakis, S., Lin, K.-Y. A., & Ghanbari, F. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.127083 · Cited by 1,340
Self-citationLi, Z., Sun, Y., Yang, Y., Han, Y., Wang, T., Chen, J., & Tsang, D. C. W. (2020) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2019.121240 · Cited by 407
Guerra-Rodríguez, S., Rodríguez, E., Singh, D., & Rodríguez-Chueca, J. (2018) · Water · doi:10.3390/w10121828 · Cited by 365
Abdul, L., Si, X., Sun, K., & Si, Y. (2021) · Journal of Environmental Chemical Engineering · doi:10.1016/j.jece.2021.105419 · Cited by 52
Metadata
- Authors
- Barzegar, G., Jorfi, S., Zarezade, V., Khatebasreh, M., Mehdipour, F., & Ghanbari, F.
- Venue
- Chemosphere
- Publisher
- Elsevier BV
- Published
- 2018-06
- Volume
- 201
- Pages
- 370-379
- ISSN
- 0045-6535 (ISSN-L)
- OpenAlex
- W2793874341
- Cited by
- 198
- References
- 1
- FWCI
- 10.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.