Wastewater treatment by anodic oxidation in electrochemical advanced oxidation process: Advance in mechanism, direct and indirect oxidation detection methods
The DOI matches its Crossref record; 80 of the 80 references it cites were found in a registry or an index.
Abstract
Electrochemical Advanced Oxidation Process (EAOP) has been applied to the degradation of refractory pollutants in wastewater due to its strong oxidation capacity, high degradation efficiency, simple operation, and mild reaction. Among electrochemical processes, anodic oxidation (AO) is the most widely used and its mechanism is mainly divided into direct oxidation and indirect oxidation. Direct oxidation means that pollutants are oxidized at the anode by direct electron transfer. Indirect oxidation refers to the generation of active species during the electrolytic reaction, which acts on pollutants. The mechanism of AO process is controlled by many factors, including electrode type, electrocatalyst material, wastewater composition, pH, applied current and voltage levels. It is very important to explore the reaction mechanism of electrochemical treatment, which determines the efficiency of the reaction, the products of the reaction, and the extent of reaction. This paper firstly reviews the current research progress on the mechanism of AO process, and summarizes in detail the different mechanisms caused by influencing factors under common AO process. Then, strategies and methods to distinguish direct oxidation and indirect oxidation mechanisms are reviewed, such as intermediate product analysis, electrochemical test analysis, active species detection, theoretical calculation, and the limitations of these methods are analyzed. Finally some suggestions are put forward for the study of the mechanism of electrochemical advanced oxidation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Direct And Mediated Anodic Oxidation of Organic Pollutants
Panizza, M., & Cerisola, G. (2009) · Chemical Reviews · doi:10.1021/cr9001319 · Cited by 2,346
Comninellis, C. (1994) · Electrochimica Acta · doi:10.1016/0013-4686(94)85175-1 · Cited by 1,621
Detection of active oxidative species in TiO2 photocatalysis using the fluorescence technique
Ishibashi, K.-I., Fujishima, A., Watanabe, T., & Hashimoto, K. (2000) · Electrochemistry Communications · doi:10.1016/s1388-2481(00)00006-0 · Cited by 1,150
Nidheesh, P. V., Zhou, M., & Oturan, M. A. (2018) · Chemosphere · doi:10.1016/j.chemosphere.2017.12.195 · Cited by 1,140
Radjenovic, J., & Sedlak, D. L. (2015) · Environmental Science & Technology · doi:10.1021/acs.est.5b02414 · Cited by 1,125
Critical review of electrochemical advanced oxidation processes for water treatment applications
Chaplin, B. P. (2014) · Environ. Sci.: Processes Impacts · doi:10.1039/c3em00679d · Cited by 862
Kissinger, P. T., & Heineman, W. R. (1983) · Journal of Chemical Education · doi:10.1021/ed060p702 · Cited by 771
Anodic oxidation of phenol for waste water treatment
Comninellis, C., & Pulgarin, C. (1991) · Journal of Applied Electrochemistry · doi:10.1007/bf01034049 · Cited by 646
Ganiyu, S. O., van Hullebusch, E. D., Cretin, M., Esposito, G., & Oturan, M. A. (2015) · Separation and Purification Technology · doi:10.1016/j.seppur.2015.09.059 · Cited by 627
Three-dimensional electrochemical process for wastewater treatment: A general review
Zhang, C., Jiang, Y., Li, Y., Hu, Z., Zhou, L., & Zhou, M. (2013) · Chemical Engineering Journal · doi:10.1016/j.cej.2013.05.033 · Cited by 583
Self-citation
Cited by
Sahu, A., & Poler, J. C. (2024) · Journal of Environmental Chemical Engineering · doi:10.1016/j.jece.2024.113754 · Cited by 229
Metadata
- Authors
- Fu, R., Zhang, P.-S., Jiang, Y.-X., Sun, L., & Sun, X.-H.
- Venue
- Chemosphere
- Publisher
- Elsevier BV
- Published
- 2023-01
- Volume
- 311
- Issue
- Pt 1
- Pages
- 136993
- ISSN
- 0045-6535 (ISSN-L)
- OpenAlex
- W4307958126
- Cited by
- 252
- References
- 80
- FWCI
- 14.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.