Inability of Diaphragm Ultrasound to Predict Extubation Failure

Vivier, Emmanuel, Muller, Michel, Putegnat, Jean-Baptiste, Steyer, Julie, Barrau, Stéphanie, Boissier, Florence, Bourdin, Gaël, Mekontso-Dessap, Armand, Levrat, Albrice, Pommier, Christian, Thille, Arnaud W. · 2019 · Chest

Abstract

BACKGROUND Diaphragmatic dysfunction may promote weaning difficulties in patients who are mechanically ventilated. OBJECTIVE The goal of this study was to assess whether diaphragm dysfunction detected by ultrasound prior to extubation could predict extubation failure in the ICU. METHODS This multicenter prospective study included patients at high risk of reintubation: those aged > 65 years, with underlying cardiac or respiratory disease, or intubated > 7 days. All patients had successfully undergone a spontaneous breathing trial. Diaphragmatic function was assessed by ultrasound prior to extubation while breathing spontaneously on a T-piece. Bilateral diaphragmatic excursion and apposition thickening fraction were measured, and diaphragmatic dysfunction was defined as excursion < 10 mm or thickening < 30%. Cough strength was clinically assessed by physiotherapists. Extubation failure was defined as reintubation or death within the 7 days following extubation. RESULTS Over a 20-month period, 191 at-risk patients were studied. Among them, 33 (17%) were considered extubation failures. The proportion of patients with diaphragmatic dysfunction was similar between those whose extubation succeeded and those whose extubation failed: 46% vs 51% using excursion (P = .55), and 71% vs 68% using thickening (P = .73), respectively. Values of excursion and thickening did not differ between the success and the failure groups: at right, excursion was 14 ± 7 mm vs 11 ± 8 (P = .13), and thickening was 29 ± 29% vs 38 ± 48% (P = .83), respectively. Extubation failure rates were 7%, 22%, and 46% in patients with effective, moderate, and ineffective cough (P < .01). Ineffective cough was the only variable independently associated with extubation failure. CONCLUSIONS Diaphragmatic dysfunction assessed by ultrasound was not associated with an increased risk of extubation failure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.chest.2019.03.004

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 179

Metadata

Authors
Vivier, E., Muller, M., Putegnat, J.-B., Steyer, J., Barrau, S., Boissier, F., Bourdin, G., Mekontso-Dessap, A., Levrat, A., Pommier, C., & Thille, A. W.
Venue
Chest
Publisher
Elsevier BV
Published
2019-06
Volume
155
Issue
6
Pages
1131-1139
ISSN
0012-3692 (ISSN-L)
OpenAlex
W2939873104
Cited by
179
References
2
FWCI
15.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Inability of Diaphragm Ultrasound to Predict Extubation Failure. https://app.cochat.ai/papers/10.1016/j.chest.2019.03.004
The paper
Vivier, E., Muller, M., Putegnat, J.-B., Steyer, J., Barrau, S., Boissier, F., Bourdin, G., Mekontso-Dessap, A., Levrat, A., Pommier, C., & Thille, A. W. (2019). Inability of Diaphragm Ultrasound to Predict Extubation Failure. Chest. https://doi.org/10.1016/j.chest.2019.03.004

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.