Ionic liquid for high temperature headspace liquid-phase microextraction of chlorinated anilines in environmental water samples
Open accessThe DOI matches its Crossref record.
Abstract
Based on the non-volatility of room temperature ionic liquids (IL), 1-butyl-3-methylimidazolium hexafluorophosphate ([C4MIM][PF6]) IL was employed as an advantageous extraction solvent for high temperature headspace liquid-phase microextraction (LPME) of chloroanilines in environmental water samples. At high temperature of 90 degrees C, 4-chloroaniline, 2-chloroaniline, 3,4-dichloroaniline, and 2,4-dichloroaniline were extracted into a 10 microl drop of [C4MIM][PF6] suspended on the needle of a high-performance liquid chromatography (HPLC) microsyringe held at the headspace of the samples. Then, the IL was injected directly into the HPLC system for determination. Parameters related to LPME were optimized, and high selectivity and low detection limits of the four chlorinated anilines were obtained because the extraction was performed at high temperature in headspace mode and the very high affinity between IL and chlorinated anilines. The proposed procedure was applied for the analysis of the real samples including tap water, river water and wastewater samples from a petrochemical plant and a printworks, and only 3,4-dichloroaniline was detected in the printworks wastewater at 88.2 microg l(-1) level. The recoveries for the four chlorinated anilines in the four samples were all in the range of 81.9-99.6% at 25 microg l(-1) spiked level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Han, X., & Armstrong, D. W. (2007) · Accounts of Chemical Research · doi:10.1021/ar700044y · Cited by 1,024
Recent Applications of Ionic Liquids in Separation Technology
Han, D., & Row, K. H. (2010) · Molecules · doi:10.3390/molecules15042405 · Cited by 560
Extraction of organic compounds with room temperature ionic liquids
Poole, C. F., & Poole, S. K. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.09.011 · Cited by 493
Pena-Pereira, F., Lavilla, I., & Bendicho, C. (2009) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2008.10.042 · Cited by 414
Developments in single-drop microextraction
Xu, L., Basheer, C., & Lee, H. K. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.10.073 · Cited by 382
Metadata
- Authors
- Peng, J.-F., Liu, J.-F., Jiang, G.-B., Tai, C., & Huang, M.-J.
- Venue
- Journal of Chromatography A
- Publisher
- Elsevier BV
- Published
- 2005-04
- Volume
- 1072
- Issue
- 1
- Pages
- 3-6
- ISSN
- 0021-9673 (ISSN-L)
- OpenAlex
- W2065527264
- Cited by
- 125
- References
- 0
- FWCI
- 7.70
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ionic liquid for high temperature headspace liquid-phase microextraction of chlorinated anilines in environmental water samples. https://app.cochat.ai/papers/10.1016/j.chroma.2004.11.060
- The paper
- Peng, J.-F., Liu, J.-F., Jiang, G.-B., Tai, C., & Huang, M.-J. (2005). Ionic liquid for high temperature headspace liquid-phase microextraction of chlorinated anilines in environmental water samples. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2004.11.060
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.