Cited by 19Analytical chemistry methods developmentAnalytical Chemistry and ChromatographyEnvironmental and Analytical Chemistry Studies

Gas chromatography with atomic emission detection for dimethylselenide and dimethyldiselenide determination in waters and plant materials using a purge-and-trap preconcentration system

Campillo, Natalia, Aguinaga, Nerea, Viñas, Pilar, López-García, Ignacio, Hernández-Córdoba, Manuel·2005·Journal of Chromatography A

Abstract

Dimethylselenide (DMSe) and dimethyldiselenide (DMDSe) were determined in plant and water samples by capillary gas chromatography using microwave induced-plasma atomic emission spectrometry for detection. The analytes were leached from the solid samples into methanol by using an ultrasonic probe, and a portion of the extract was preconcentrated by means of a purge-and-trap system before being chromatographed. The analytes were directly purged from the water samples in the presence of 6% (v/v) methanol. Element-specific detection and quantification was carried out by monitoring the selenium (196 nm) emission line. Calibration curves were obtained by plotting peak area versus concentration and the correlation coefficients for linear calibration were 0.9999 for both analytes. Detection limits of 0.8 and 1.1 ng l(-1) were obtained for DMSe and DMDSe, respectively, for water samples. For plant materials, the detection limits calculated for 0.5 g samples were 0.3 and 0.4 ng g(-1) for DMSe and DMDSe, respectively. Concentration levels of DMSe ranging from 1.2 to 4.2 ng g(-1) were found in some of the plant materials analyzed. No DMDSe was found in any of the samples. The accuracy of the method was checked by analyzing different spiked water and plant samples.

Integrity signals

Registry

Crossref · 10.1016/j.chroma.2005.08.002

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Concentrations of up to 9 nM DMSe and 11 nM DMDSe have been measured in river sediments, while in river water up to 37 pM DMSe has been quantified.

    “Concentrations of up to 9 nM DMSe and 11 nM DMDSe have been measured in river sediments [254], while in river water up to 37 pM DMSe has been quantified [255].”

Cited by

Sorted by citations

Authors
Campillo, N., Aguinaga, N., Viñas, P., López-García, I., & Hernández-Córdoba, M.
Affiliations
Universidad de Murcia (ES)
Venue
Journal of Chromatography A
Publisher
Elsevier BV
Published
2005-11
Volume
1095
Issue
1-2
Pages
138-144
ISSN
0021-9673 (ISSN-L)
OpenAlex
W2033548694
Cited by
19
References
0
Citations by year
2026: 1 · 2025: 4 · 2023: 1 · 2016: 1 · 2015: 1 · 2013: 1 · 2012: 2
FWCI
1.36
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Chromatography A (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Ministerio de Economía y Competitividad
  • Comunidad Autónoma de la Región de Murcia
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Physical Sciences › Chemistry › Spectroscopy › Analytical Chemistry and Chromatography
  • Physical Sciences › Environmental Science › Water Science and Technology › Environmental and Analytical Chemistry Studies
Keywords
dimethylselenide, ultrasound-assisted extraction, plant material, water samples
MeSH terms
Chromatography, Gas, Poaceae, Plants, Spectrophotometry, Atomic, Vegetables, Water Pollutants, Chemical, Organoselenium Compounds

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review