Cited by 77Analytical chemistry methods developmentAnalytical Chemistry and ChromatographyAnalytical Methods in Pharmaceuticals

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Suitable conditions for liquid-phase microextraction using solidification of a floating drop for extraction of fat-soluble vitamins established using an orthogonal array experimental design

Sobhi, Hamid Reza, Yamini, Yadollah, Esrafili, Ali, Abadi, Reza Haji Hosseini Baghdad·2008·Journal of Chromatography A

Abstract

A simple, rapid and efficient microextraction method for the extraction and determination of some fat-soluble vitamins (A, D2, D3) in aqueous samples was developed. For the first time orthogonal array designs (OADs) were employed to screen the liquid-phase microextraction (LPME) method in which few microliters of 1-undecanol were delivered to the surface of the aqueous sample and it was agitated for a selected time. Then sample vial was cooled by inserting it into an ice bath for 5 min. The solidified solvent was transferred into a suitable vial and immediately melted. Then, the extract was directly injected into a high-performance liquid chromatography (HPLC) for analysis. Several factors affecting the microextraction efficiency such as sample solution temperature, stirring speed, volume of the organic solvent, ionic strength and extraction time were investigated and screened using an OA16 (4(5)) matrix. Under the best conditions (temperature, 55 degrees C; stirring speed, 1000 rpm; the volume of extracting solvent, 15.0 microL; no salt addition and extraction time, 60 min), detection limits of the method were in the range of 1.0-3.5 microgL(-1). The relative standard deviations (RSDs) to determine the vitamins at microg L(-1) levels by applying the proposed method varied in the range of 5.1-10.7%. Dynamic linear ranges of 5-500 mugL(-1) with good correlation coefficients (0.9984<r(2)<0.9991) were observed. Finally, the study was applied to determine the vitamins in several…

Overview

Integrity signals

Registry

Crossref · 10.1016/j.chroma.2008.05.005

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Flagged first, then by citations

Research works printed but not linked: 23

  1. Luque-Garcia, 2001, J. Chromatogr. A, 935, 3, 10.1016/S0021-9673(01)01118-9 · DOI
  2. Burri, 2003, J. Chromatogr. A, 987, 359, 10.1016/S0021-9673(02)01908-8 · DOI
  3. Binkley, 2000, Nutr. Rev., 58, 138, 10.1111/j.1753-4887.2000.tb01848.x · DOI
  4. Quesada, 2004, J. Steroid Biochem. Mol. Biol., 89, 473, 10.1016/j.jsbmb.2004.03.056 · DOI
  5. Koshy, 1982, J. Pharm. Sci., 71, 137, 10.1002/jps.2600710203 · DOI
  6. Anderson, 1994, J. Nutr. Biochem., 5, 58, 10.1016/0955-2863(94)90018-3 · DOI
  7. Audran, 1985, Mayo Clin. Proc., 60, 851, 10.1016/S0025-6196(12)64791-0 · DOI
  8. Mart́ınez Gómez, 1999, Rev. Méd. Españ. Enferm. Metab. Óseas, 8, 5
  9. Hollis, 1996, Calcif. Tissue Int., 58, 4, 10.1007/BF02509538 · DOI
  10. Brunetto, 2004, Talanta, 64, 1364, 10.1016/j.talanta.2004.04.035 · DOI
  11. Liu, 1996, Anal. Chem., 68, 1817, 10.1021/ac960145h · DOI
  12. Jeannot, 1997, Anal. Chem., 69, 235, 10.1021/ac960814r · DOI
  13. Liu, 2000, Anal. Chem., 72, 4462, 10.1021/ac000240x · DOI
  14. Lowri, 2001, J. Chromatogr. A, 911, 97, 10.1016/S0021-9673(00)01256-5 · DOI
  15. Bagheri, 2004, J. Chromatogr. A, 1046, 27, 10.1016/j.chroma.2004.06.062 · DOI
  16. Pedersen-Bjergaard, 1999, Anal. Chem., 71, 2650, 10.1021/ac990055n · DOI · Paper page
  17. Lan, 1994, Analyst, 119, 1659, 10.1039/an9941901659 · DOI
  18. Lan, 1994, Analyst, 119, 1669, 10.1039/an9941901669 · DOI
  19. Lan, 1995, Analyst, 120, 273, 10.1039/an9952000273 · DOI
  20. Lan, 1995, Analyst, 120, 281, 10.1039/an9952000281 · DOI
  21. Wu, 2005, J. Chromatogr. A, 1092, 182, 10.1016/j.chroma.2005.07.032 · DOI
  22. Khalili-Zanjani, 2007, Anal. Chim. Acta, 585, 286, 10.1016/j.aca.2006.12.049 · DOI · Paper page
  23. Wai, 1997, J. Chromatogr. A, 785, 369, 10.1016/S0021-9673(97)00679-1 · DOI

Cited by

Sorted by citations

Metadata

Authors
Sobhi, H. R., Yamini, Y., Esrafili, A., & Abadi, R. H. H. B.
Affiliations
  • University of Tehran (IR)
  • Tarbiat Modares University (IR)
Corresponding author
Yamini, Yadollah
Venue
Journal of Chromatography A
Publisher
Elsevier BV
Published
2008-07
Volume
1196-1197
Pages
28-32
ISSN
0021-9673 (ISSN-L)
OpenAlex
W2025864642
Cited by
77
References
1
Citations by year
2025: 1 · 2024: 4 · 2020: 1 · 2019: 2 · 2018: 2 · 2017: 2 · 2016: 2 · 2015: 5 · 2014: 11 · 2013: 12 · 2012: 8
FWCI
9.08
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Chromatography A (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
Keywords
liquid-phase microextraction, fat-soluble vitamins, vitamin A, vitamin D2, vitamin D3, 1-undecanol, orthogonal experimental design, extraction optimization, aqueous sample, urine, tap water, fruit juice
MeSH terms
Fats, Chemical Fractionation, Solubility, Vitamins, Reproducibility of Results

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review