Cited by 57Mass Spectrometry Techniques and ApplicationsAnalytical Methods in PharmaceuticalsAnalytical Chemistry and Chromatography

Development of sensitive derivatization method for aldosterone in liquid chromatography–electrospray ionization tandem mass spectrometry of corticosteroids

Yamashita, Kouwa, Okuyama, Mitsunobu, Nakagawa, Risa, Honma, Seijiro, Satoh, Fumitoshi, Morimoto, Ryo, Ito, Sadayoshi, Takahashi, Madoka +1 more·2008·Journal of Chromatography A

Abstract

A highly sensitive quantification method of aldosterone by liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) was investigated in a positive mode using recently developed picolinyl derivatization. Aldosterone was smoothly and quantitatively converted to the ethyl ether-picolinyl derivative by treatment with HCl-ethanol followed by the esterification with picolinic acid in the presence of 2-methyl-6-nitrobenzoic anhydride and 4-dimethylaminopyridine. The positive ion-ESI mass spectrum of the ethyl ether-picolinyl derivative was characterized by an appearance of protonated molecule ([M+H](+)) as a base peak. The ethyl ether-picolinyl derivatization gave a successful result in a separation of aldosterone from corticosterone, dehydrocorticosterone and cortexolone, and also provided an approximately 10-fold higher ESI response in the positive-LC-ESI-MS/MS (selected reaction monitoring; SRM) when compared to that of underivatized molecule (negative mode). The limit of quantification of aldosterone by SRM using ethyl ether-picolinyl derivatization (m/z 494-->m/z 448) was 1 pg/0.2 ml serum with accuracy and precision of 92.6% and 5.6%, respectively.

Integrity signals

Registry

Crossref · 10.1016/j.chroma.2008.05.034

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

The citation lists haven’t been fetched yet

References 28 · Cited by 57

Authors
Yamashita, K., Okuyama, M., Nakagawa, R., Honma, S., Satoh, F., Morimoto, R., Ito, S., Takahashi, M., & Numazawa, M.
Affiliations
  • Tohoku Medical and Pharmaceutical University (JP)
  • Tohoku University (JP)
Corresponding author
Yamashita, Kouwa
Venue
Journal of Chromatography A
Publisher
Elsevier BV
Published
2008-07
Volume
1200
Issue
2
Pages
114-121
ISSN
0021-9673 (ISSN-L)
OpenAlex
W2031327647
Cited by
57
References
28
Citations by year
2026: 1 · 2025: 1 · 2024: 3 · 2023: 1 · 2022: 3 · 2021: 1 · 2019: 2 · 2018: 1 · 2017: 3 · 2016: 4 · 2015: 7 · 2014: 5 · 2013: 5 · 2012: 6
FWCI
2.02
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Chromatography A (publishedVersion)
  • PubMed (publishedVersion)
Funders
Ministry of Education, Culture, Sports, Science and Technology
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
  • Physical Sciences › Chemistry › Spectroscopy › Analytical Chemistry and Chromatography
Keywords
aldosterone, corticosteroids, LC-ESI-MS/MS, multiple reaction monitoring, corticosterone, cortexolone, positive ion detection
MeSH terms
Adrenal Cortex Hormones, Ethanol, Aldosterone, Chromatography, High Pressure Liquid, Humans, Hydrochloric Acid, Picolinic Acids, Reproducibility of Results, Molecular Structure, Spectrometry, Mass, Electrospray Ionization, Tandem Mass Spectrometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›