The DOI matches its Crossref record.
Comprehensive blood plasma lipidomics by liquid chromatography/quadrupole time-of-flight mass spectrometry
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Psychogios, N., Hau, D. D., Peng, J., Guo, A. C., Mandal, R., Bouatra, S., Sinelnikov, I., Krishnamurthy, R., Eisner, R., Gautam, B., et al. (2011) · PLoS ONE · doi:10.1371/journal.pone.0016957 · Cited by 1,703
LipidBlast in silico tandem mass spectrometry database for lipid identification
Kind, T., Liu, K.-H., Lee, D. Y., DeFelice, B., Meissen, J. K., & Fiehn, O. (2013) · Nature Methods · doi:10.1038/nmeth.2551 · Cited by 981
Comprehensive analysis of lipids in biological systems by liquid chromatography-mass spectrometry
Cajka, T., & Fiehn, O. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.04.017 · Cited by 650
Identification of small molecules using accurate mass MS/MS search
Kind, T., Tsugawa, H., Cajka, T., Ma, Y., Lai, Z., Mehta, S. S., Wohlgemuth, G., Barupal, D. K., Showalter, M. R., Arita, M., et al. (2018) · Mass Spectrometry Reviews · doi:10.1002/mas.21535 · Cited by 479
Quality assurance procedures for mass spectrometry untargeted metabolomics. a review
Dudzik, D., Barbas-Bernardos, C., García, A., & Barbas, C. (2018) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2017.07.044 · Cited by 344
Metadata
- Authors
- Sandra, K., Pereira, A. D. S., Vanhoenacker, G., David, F., & Sandra, P.
- Venue
- Journal of Chromatography A
- Publisher
- Elsevier BV
- Published
- 2010-06
- Volume
- 1217
- Issue
- 25
- Pages
- 4087-4099
- ISSN
- 0021-9673 (ISSN-L)
- OpenAlex
- W2148089123
- Cited by
- 197
- References
- 0
- FWCI
- 5.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comprehensive blood plasma lipidomics by liquid chromatography/quadrupole time-of-flight mass spectrometry. https://app.cochat.ai/papers/10.1016/j.chroma.2010.02.039
- The paper
- Sandra, K., Pereira, A. D. S., Vanhoenacker, G., David, F., & Sandra, P. (2010). Comprehensive blood plasma lipidomics by liquid chromatography/quadrupole time-of-flight mass spectrometry. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2010.02.039
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.