The DOI matches its Crossref record.
Hypercrosslinking: New approach to porous polymer monolithic capillary columns with large surface area for the highly efficient separation of small molecules
Open accessAbstract
Monolithic polymers with an unprecedented surface area of over 600 m2/g have been prepared from a poly(styrene-co-vinylbenzyl chloride-co-divinylbenzene) precursor monolith that was swollen in 1,2-dichloroethane and hypercrosslinked via Friedel-Crafts reaction catalyzed by ferric chloride. Both the composition of the reaction mixture used for the preparation of the precursor monolith and the conditions of the hypercrosslinking reaction have been varied using mathematical design of experiments and the optimized system validated. Hypercrosslinked monolithic capillary columns contain an array of small pores that make the column ideally suited for the high efficiency isocratic separations of small molecules such as uracil and alkylbenzenes with column efficiencies reproducibly exceeding 60,000 plates/m for retained compounds. The separation process could be accelerated while also improving peak shape through the use of higher temperatures and a ternary mobile phase consisting of acetonitrile, tetrahydrofuran, and water. As a result, seven compounds were well separated in less than 2 min. These columns also facilitate separations of peptide mixtures such as a tryptic digest of cytochrome c using a gradient elution mode which affords a sequence coverage of 93%. A 65 cm long hypercrosslinked capillary column used in size exclusion mode with tetrahydrofuran as the mobile phase afforded almost baseline separation of toluene and five polystyrene standards.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hypercrosslinked porous polymer materials: design, synthesis, and applications
Tan, L., & Tan, B. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00851h · Cited by 1,357
Experimental design in chromatography: A tutorial review
Hibbert, D. B. (2012) · Journal of Chromatography B · doi:10.1016/j.jchromb.2012.01.020 · Cited by 449
Hypercrosslinked Polymers: A Review
Huang, J., & Turner, S. R. (2018) · Polymer Reviews · doi:10.1080/15583724.2017.1344703 · Cited by 313
Jandera, P., & Janás, P. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.01.060 · Cited by 309
The integration of flow reactors into synthetic organic chemistry
Baxendale, I. R. (2013) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.4012 · Cited by 255
Metadata
- Authors
- Urban, J., Svec, F., & Fréchet, J. M. J.
- Venue
- Journal of Chromatography A
- Publisher
- Elsevier BV
- Published
- 2010-12
- Volume
- 1217
- Issue
- 52
- Pages
- 8212-8221
- ISSN
- 0021-9673 (ISSN-L)
- OpenAlex
- W2145655240
- Cited by
- 160
- References
- 0
- FWCI
- 6.91
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hypercrosslinking: New approach to porous polymer monolithic capillary columns with large surface area for the highly efficient separation of small molecules. https://app.cochat.ai/papers/10.1016/j.chroma.2010.10.100
- The paper
- Urban, J., Svec, F., & Fréchet, J. M. J. (2010). Hypercrosslinking: New approach to porous polymer monolithic capillary columns with large surface area for the highly efficient separation of small molecules. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2010.10.100
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.