Cited by 121Per- and polyfluoroalkyl substances researchAnalytical chemistry methods developmentPesticide Residue Analysis and Safety

Simultaneous determination of perfluoroalkyl phosphonates, carboxylates, and sulfonates in drinking water

Ullah, Shahid, Alsberg, Tomas, Berger, Urs·2011·Journal of Chromatography A

Abstract

A trace analytical method based on high performance liquid chromatography coupled to quadrupole time-of-flight high resolution mass spectrometry was developed for simultaneous determination of perfluoroalkyl phosphonates (PFPAs, carbon chain lengths C6,8,10), perfluoroalkyl carboxylates (PFCAs, C5-12), and perfluoroalkyl sulfonates (PFSAs, C4,6,8,10) in drinking water (tap water). Analytes were enriched on a mixed mode co-polymeric sorbent (C8+quaternary amine) using solid phase extraction. Chromatographic separation was achieved on a Zorbax Extend C18 reversed phase column using a mobile phase gradient consisting of water, methanol, and acetonitrile containing 2mM ammonium acetate and 5 mM 1-methyl piperidine. The mass spectrometer was operated in electrospray negative ion mode. Use of 1-methyl piperidine in the mobile phase resulted in a significant increase in instrument sensitivity for PFPAs through improved chromatographic resolution, background suppression, and increased ionization efficiency. Method detection limits for extraction of 500 mL tap water were in the ranges of 0.095-0.17 ng/L, 0.027-0.17 ng/L, and 0.014-0.052 ng/L for PFPAs, PFCAs, and PFSAs, respectively. Whole method recoveries at a spiking level of 0.5 ng/L to 500 mL HPLC grade water were 40-56%, 56-97%, and 55-77% for PFPAs, PFCAs, and PFSAs, respectively. A matrix effect (signal enhancement) was observed in the detection of PFPAs in tap water extracts, leading to calculated recoveries of 249-297% at a 0.5 ng/L spiking level. This effect resulted in an additional improvement of method sensitivity for PFPAs. To compensate for the matrix effect, PFPAs in tap water were quantified using matrix-matched and extracted calibration standards. The method was successfully applied to the analysis of drinking water collected from six European countries. PFPAs were not detected except for perfluorooctyl phosphonate (PFOPA) at close to the detection limit of 0.095 ng/L in two water samples from Amsterdam, the Netherlands. Highest levels were found for perfluorobutane sulfonate (PFBS, 18.8 ng/L) and perfluorooctanoate (PFOA, 8.6 ng/L) in samples from Amsterdam as well as for perfluorooctane sulfonate (PFOS, 8.8 ng/L) in tap water from Stockholm, Sweden.

Integrity signals

Registry

Crossref · 10.1016/j.chroma.2011.07.005

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

The citation lists haven’t been fetched yet

References 30 · Cited by 121

Authors
Ullah, S., Alsberg, T., & Berger, U.
Affiliations
Stockholm University (SE)
Corresponding author
Berger, Urs
Venue
Journal of Chromatography A
Publisher
Elsevier BV
Published
2011-09
Volume
1218
Issue
37
Pages
6388-6395
ISSN
0021-9673 (ISSN-L)
OpenAlex
W2064562166
Cited by
121
References
30
Citations by year
2026: 6 · 2025: 5 · 2024: 4 · 2023: 8 · 2022: 9 · 2021: 4 · 2020: 10 · 2019: 7 · 2018: 1 · 2017: 13 · 2016: 7 · 2015: 18 · 2014: 8 · 2013: 15 · 2012: 4
FWCI
7.08
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Chromatography A (publishedVersion)
  • PubMed (publishedVersion)
Funders
European Commission
Topics
  • Physical Sciences › Environmental Science › Environmental Chemistry › Per- and polyfluoroalkyl substances research
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Life Sciences › Agricultural and Biological Sciences › Food Science › Pesticide Residue Analysis and Safety
Keywords
perfluoroalkyl carboxylates, perfluoroalkyl sulfonates
MeSH terms
Acetonitriles, Methanol, Alkanesulfonates, Chromatography, High Pressure Liquid, Europe, Fluorocarbons, Piperidines, Sensitivity and Specificity, Mass Spectrometry, Water Pollutants, Chemical, Water Supply, Reproducibility of Results, Organophosphonates

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review