Simultaneous determination of perfluoroalkyl phosphonates, carboxylates, and sulfonates in drinking water
Abstract
A trace analytical method based on high performance liquid chromatography coupled to quadrupole time-of-flight high resolution mass spectrometry was developed for simultaneous determination of perfluoroalkyl phosphonates (PFPAs, carbon chain lengths C6,8,10), perfluoroalkyl carboxylates (PFCAs, C5-12), and perfluoroalkyl sulfonates (PFSAs, C4,6,8,10) in drinking water (tap water). Analytes were enriched on a mixed mode co-polymeric sorbent (C8+quaternary amine) using solid phase extraction. Chromatographic separation was achieved on a Zorbax Extend C18 reversed phase column using a mobile phase gradient consisting of water, methanol, and acetonitrile containing 2mM ammonium acetate and 5 mM 1-methyl piperidine. The mass spectrometer was operated in electrospray negative ion mode. Use of 1-methyl piperidine in the mobile phase resulted in a significant increase in instrument sensitivity for PFPAs through improved chromatographic resolution, background suppression, and increased ionization efficiency. Method detection limits for extraction of 500 mL tap water were in the ranges of 0.095-0.17 ng/L, 0.027-0.17 ng/L, and 0.014-0.052 ng/L for PFPAs, PFCAs, and PFSAs, respectively. Whole method recoveries at a spiking level of 0.5 ng/L to 500 mL HPLC grade water were 40-56%, 56-97%, and 55-77% for PFPAs, PFCAs, and PFSAs, respectively. A matrix effect (signal enhancement) was observed in the detection of PFPAs in tap water extracts, leading to calculated recoveries of 249-297% at a 0.5 ng/L spiking level. This effect resulted in an additional improvement of method sensitivity for PFPAs. To compensate for the matrix effect, PFPAs in tap water were quantified using matrix-matched and extracted calibration standards. The method was successfully applied to the analysis of drinking water collected from six European countries. PFPAs were not detected except for perfluorooctyl phosphonate (PFOPA) at close to the detection limit of 0.095 ng/L in two water samples from Amsterdam, the Netherlands. Highest levels were found for perfluorobutane sulfonate (PFBS, 18.8 ng/L) and perfluorooctanoate (PFOA, 8.6 ng/L) in samples from Amsterdam as well as for perfluorooctane sulfonate (PFOS, 8.8 ng/L) in tap water from Stockholm, Sweden.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Several studies have reported PFASs in drinking water in the Netherlands.
“Several studies have reported on the presence of PFASs in drinking water in The Netherlands.14,18”
From Presence of Emerging Per- and Polyfluoroalkyl Substances (PFASs) in River and Drinking Water near a Fluorochemical Production Plant in the Netherlands (2017) · cites this paper as [18]
The citation lists haven’t been fetched yet
References 30 · Cited by 121
- Authors
- Ullah, S., Alsberg, T., & Berger, U.
- Affiliations
- Stockholm University (SE)
- Corresponding author
- Berger, Urs
- Venue
- Journal of Chromatography A
- Publisher
- Elsevier BV
- Published
- 2011-09
- Volume
- 1218
- Issue
- 37
- Pages
- 6388-6395
- ISSN
- 0021-9673 (ISSN-L)
- OpenAlex
- W2064562166
- Cited by
- 121
- References
- 30
- Citations by year
- 2026: 6 · 2025: 5 · 2024: 4 · 2023: 8 · 2022: 9 · 2021: 4 · 2020: 10 · 2019: 7 · 2018: 1 · 2017: 13 · 2016: 7 · 2015: 18 · 2014: 8 · 2013: 15 · 2012: 4
- FWCI
- 7.08
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Chromatography A (publishedVersion)
- PubMed (publishedVersion)
- Funders
- European Commission
- Topics
- Physical Sciences › Environmental Science › Environmental Chemistry › Per- and polyfluoroalkyl substances research
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Life Sciences › Agricultural and Biological Sciences › Food Science › Pesticide Residue Analysis and Safety
- Keywords
- perfluoroalkyl carboxylates, perfluoroalkyl sulfonates
- MeSH terms
- Acetonitriles, Methanol, Alkanesulfonates, Chromatography, High Pressure Liquid, Europe, Fluorocarbons, Piperidines, Sensitivity and Specificity, Mass Spectrometry, Water Pollutants, Chemical, Water Supply, Reproducibility of Results, Organophosphonates
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review