The DOI matches its Crossref record.
Determination of partition coefficients of refrigerants by gas liquid chromatographic headspace analysis
Abstract
Gas-water partition coefficients, K(w), and gas-solvent partition coefficients, K(s), have been determined for chlorodifluoromethane and for 1,1,1,3,3,3-hexafluoropropane by headspace analysis, using a very simple experimental procedure. These partition coefficients then yield water-solvent partition coefficients, P(s). Where comparisons can be made there is excellent agreement with literature values for K(w) and P(s). The obtained values of K(s) and P(s) can be used to obtain physicochemical properties, or descriptors, for the refrigerants. Combination of these descriptors with previous equations we have developed enables partition coefficients to be obtained for a host of systems.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Descriptors for very short PFAS (C≤3, mostly refrigerants) have been reported.
“descriptors for very short PFAS (C≤3, mostly refrigerants) have been reported,13,14”
From Intermolecular Interactions, Solute Descriptors, and Partition Properties of Neutral Per- and Polyfluoroalkyl Substances (PFAS) (2023) · cites this paper as [13]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 26
- Dearden, 1985, Environ. Health Perspect., 61, 203, 10.1289/ehp.8561203 · DOI
- Dearden, 1985, Quant. Struct. Act. Relat., 7, 133, 10.1002/qsar.19880070304 · DOI
- Giaginis, 2008, J. Liq. Chromatogr. Relat. Technol., 31, 79, 10.1080/10826070701665626 · DOI
- Abraham, 1971, J. Chem. Soc. A, 1061, 10.1039/j19710001061 · DOI
- Abraham, 1974, J. Chem. Thermodyn., 6, 1175, 10.1016/0021-9614(74)90154-2 · DOI
- Zenkovich, 2007, J. Chromatogr. A, 1150, 117, 10.1016/j.chroma.2006.08.083 · DOI
- Abraham, 1993, Chem. Soc. Rev., 22, 73, 10.1039/cs9932200073 · DOI · Paper page
- Abraham, 2004, J. Chromatogr. A, 1037, 29, 10.1016/j.chroma.2003.12.004 · DOI · Paper page
- Abraham, 2010, J. Pharm. Sci., 99, 1500, 10.1002/jps.21922 · DOI
- Stephens, 2012, Global J. Phys. Chem., 3, 1
- Abraham, 1987, Chromatographia, 23, 243, 10.1007/BF02311772 · DOI
- D.P. Walsh, Ph.D. Thesis, University of London, 1992.
- Wahlström, 1996, Can. J. Chem. Eng., 74, 426, 10.1002/cjce.5450740316 · DOI
- Abraham, 2006, J. Chem. Inf. Model., 46, 1735, 10.1021/ci060047p · DOI
- Bruno, 1996, Anal. Chem., 68, 1347, 10.1021/ac9510191 · DOI
- Abraham, 2007, Fluid Phase Equilibr., 251, 93, 10.1016/j.fluid.2006.11.007 · DOI
- Sprunger, 2009, Fluid Phase Equilibr., 286, 170, 10.1016/j.fluid.2009.09.004 · DOI
- Stephens, 2011, Open Thermodyn. J., 5, 104, 10.2174/1874396X01105010104 · DOI
- Abraham, 2001, Fluid Phase Equilibr., 180, 41, 10.1016/S0378-3812(00)00511-2 · DOI · Paper page
- Hine, 1975, J. Org. Chem., 40, 292, 10.1021/jo00891a006 · DOI
- Wilhelm, 1977, Chem. Rev., 77, 219, 10.1021/cr60306a003 · DOI
- Woollen, 1992, Int. Arch. Occup. Environ. Health, 64, 383, 10.1007/BF00379550 · DOI
- Abraham, 2006, Eur. J. Med. Chem., 41, 1430, 10.1016/j.ejmech.2006.07.012 · DOI
- Abraham, 2005, Chem. Res. Toxicol., 18, 904, 10.1021/tx050066d · DOI
- Kojima, 1970, J. Inorg. Nucl. Chem., 32, 987, 10.1016/0022-1902(70)80078-1 · DOI
- Simpson, 1974, J. Lipid Res., 15, 415, 10.1016/S0022-2275(20)36790-0 · DOI
Cited by
Sorted by citations
Endo, S. (2023) · Environmental Science & Technology · doi:10.1021/acs.est.3c07503 · Cited by 48
Metadata
- Authors
- Abraham, M. H., Gil-Lostes, J., Corr, S., & Acree, W. E.
- Venue
- Journal of Chromatography A
- Publisher
- Elsevier BV
- Published
- 2012-11
- Volume
- 1265
- Pages
- 144-148
- ISSN
- 0021-9673
- Cited by
- 3
- References
- 0
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review