Nanofluid of zinc oxide nanoparticles in ionic liquid for single drop liquid microextraction of fungicides in environmental waters prior to high performance liquid chromatographic analysis
Open accessThe DOI matches its Crossref record.
Abstract
Using a nanofluid obtained by dispersing ZnO nanoparticles (ZnO NPs) in 1-hexyl-3-methylimidazolium hexafluorophosphate, new single drop microextraction method was developed for simultaneous extraction of three fungicides (chlorothalonil, kresoxim-methyl and famoxadone) in water samples prior to their analysis by high performance liquid chromatography (HPLC-VWD). The parameters affecting the extraction efficiency such as amount of ZnO NPs in the nanofluid, solvent volume, extraction time, stirring rate, pH and ionic strength of the sample solution were optimized. Under the optimized conditions, the limits of detection were in the range of 0.13-0.19ng/mL, the precision of the method assessed with intra-day and inter-day relative standard deviations were <4.82% and <7.04%, respectively. The proposed method was successfully applied to determine the three fungicides in real water samples including lake water, river water, as well as effluent and influent of wastewater treatment plant, with recoveries in the range of 74.94-96.11% at 5ng/mL spiking level. Besides to being environmental friendly, the high enrichment factor and the data quality obtained with the proposed method demonstrated its potential for application in multi residue analysis of fungicides in actual water samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pesticides pollution: Classifications, human health impact, extraction and treatment techniques
Hassaan, M. A., & El Nemr, A. (2020) · Egyptian Journal of Aquatic Research · doi:10.1016/j.ejar.2020.08.007 · Cited by 633
Mishra, R. K., Mentha, S. S., Misra, Y., & Dwivedi, N. (2023) · Water-Energy Nexus · doi:10.1016/j.wen.2023.08.002 · Cited by 505
Environmental Application, Fate, Effects, and Concerns of Ionic Liquids: A Review
Amde, M., Liu, J.-F., & Pang, L. (2015) · Environmental Science & Technology · doi:10.1021/acs.est.5b03123 · Cited by 491
Self-citationSamsidar, A., Siddiquee, S., & Shaarani, S. M. (2018) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2017.11.011 · Cited by 416
Extraction with environmentally friendly solvents
Płotka-Wasylka, J., Rutkowska, M., Owczarek, K., Tobiszewski, M., & Namieśnik, J. (2017) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.03.006 · Cited by 383
Metadata
- Authors
- Amde, M., Tan, Z.-Q., Liu, R., & Liu, J.-F.
- Venue
- Journal of Chromatography A
- Publisher
- Elsevier BV
- Published
- 2015-05
- Volume
- 1395
- Pages
- 7-15
- ISSN
- 0021-9673 (ISSN-L)
- OpenAlex
- W2045076280
- Cited by
- 76
- References
- 0
- FWCI
- 7.26
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nanofluid of zinc oxide nanoparticles in ionic liquid for single drop liquid microextraction of fungicides in environmental waters prior to high performance liquid chromatographic analysis. https://app.cochat.ai/papers/10.1016/j.chroma.2015.03.049
- The paper
- Amde, M., Tan, Z.-Q., Liu, R., & Liu, J.-F. (2015). Nanofluid of zinc oxide nanoparticles in ionic liquid for single drop liquid microextraction of fungicides in environmental waters prior to high performance liquid chromatographic analysis. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2015.03.049
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.