A hydrophobic deep eutectic solvent based vortex-assisted liquid-liquid microextraction for the determination of formaldehyde from biological and indoor air samples by high performance liquid chromatography
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Hydrophobic deep eutectic solvents (DESs) are a new class of green solvents, and their research and application are a brand new area. So far, only a few hydrophobic DESs have been reported as extraction solvents. In this paper, five kinds of hydrophobic DESs composed of trioctylmethylammonium chloride and hydroquinone, 4-phenylphenol or 4-cyanophenol are designed and prepared for the first time. Melting point / glass transition temperature and density are also determined for these DESs. Coupled with HPLC, these hydrophobic DESs have been used as extractants in vortex-assisted liquid-liquid microextraction for the selective enrichment and indirect determination of formaldehyde. The optimization of reaction and extraction conditions, such as pH value, reaction time and temperature, concentration of 2,4-dinitrophenylhydrazine, type and dosage of the extraction solvent, speed and time of vortex, salt addition and centrifugation time are investigated in detail. It is found that under the optimized experimental conditions, the calibration curve of this method is linear in the range of 1.0-200.0 μg L-1 with the linear correlation coefficient (r2) of 0.9994. The limit of detection (S/N = 3) and limit of quantification (S/N = 10) are 0.2 μg L-1 and 1.0 μg L-1, and the intra-day and inter-day precision (RSD, n = 5) are 1.1% and 3.5%, respectively. The interference of some common coexisting ions and neutral molecules have been also tested. The proposed method has been successfully used for the determination of formaldehyde from biological and indoor air samples. The recovery of formaldehyde is in the range from 83.1% to 104.4%, and the relative standard deviation is lower than 5.9%. Furthermore, the analytical parameters of the proposed method have been compared with other extraction and microextraction methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrophobic deep eutectic solvents as water-immiscible extractants
van Osch, D. J. G. P., Zubeir, L. F., van den Bruinhorst, A., Rocha, M. A. A., & Kroon, M. C. (2015) · Green Chemistry · doi:10.1039/c5gc01451d · Cited by 987
Menthol-based Eutectic Mixtures: Hydrophobic Low Viscosity Solvents
Ribeiro, B. D., Florindo, C., Iff, L. C., Coelho, M. A. Z., & Marrucho, I. M. (2015) · ACS Sustainable Chemistry & Engineering · doi:10.1021/acssuschemeng.5b00532 · Cited by 672
Makoś, P., Przyjazny, A., & Boczkaj, G. (2018) · Journal of Chromatography A · doi:10.1016/j.chroma.2018.07.070 · Cited by 342
Deng, W., Yu, L., Li, X., Chen, J., Wang, X., Deng, Z., & Xiao, Y. (2019) · Food Chemistry · doi:10.1016/j.foodchem.2018.09.048 · Cited by 168
Zhu, S., Zhou, J., Jia, H., & Zhang, H. (2018) · Food Chemistry · doi:10.1016/j.foodchem.2017.09.141 · Cited by 166
Deep eutectic solvent-based dispersive liquid-liquid microextraction
Farajzadeh, M. A., Afshar Mogaddam, M. R., & Aghanassab, M. (2016) · Analytical Methods · doi:10.1039/c5ay03189c · Cited by 141
Wang, H., Hu, L., Liu, X., Yin, S., Lu, R., Zhang, S., Zhou, W., & Gao, H. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.07.073 · Cited by 118
Cited by
Cao, J., & Su, E. (2021) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2021.127965 · Cited by 345
van Osch, D. J. G. P., Dietz, C. H. J. T., Warrag, S. E. E., & Kroon, M. C. (2020) · ACS Sustainable Chemistry & Engineering · doi:10.1021/acssuschemeng.0c00559 · Cited by 270
Tang, W., An, Y., & Row, K. H. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116187 · Cited by 209
Devi, M., Moral, R., Thakuria, S., Mitra, A., & Paul, S. (2023) · ACS Omega · doi:10.1021/acsomega.2c07684 · Cited by 194
El-Deen, A. K., & Shimizu, K. (2019) · Microchemical Journal · doi:10.1016/j.microc.2019.103988 · Cited by 93
Metadata
- Authors
- Zhang, K., Liu, C., Li, S., & Fan, J.
- Venue
- Journal of Chromatography A
- Publisher
- Elsevier BV
- Published
- 2019-03
- Volume
- 1589
- Pages
- 39-46
- ISSN
- 0021-9673 (ISSN-L)
- OpenAlex
- W2907409737
- Cited by
- 61
- References
- 7
- FWCI
- 4.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A hydrophobic deep eutectic solvent based vortex-assisted liquid-liquid microextraction for the determination of formaldehyde from biological and indoor air samples by high performance liquid chromatography. https://app.cochat.ai/papers/10.1016/j.chroma.2018.12.063
- The paper
- Zhang, K., Liu, C., Li, S., & Fan, J. (2019). A hydrophobic deep eutectic solvent based vortex-assisted liquid-liquid microextraction for the determination of formaldehyde from biological and indoor air samples by high performance liquid chromatography. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2018.12.063
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.