Column packing elimination in matrix solid phase dispersion by using water compatible magnetic molecularly imprinted polymer for recognition of melamine from milk samples
The DOI matches its Crossref record.
Abstract
This paper reports a new variant of sample clean-up procedure based on miniaturized matrix solid phase dispersion (MSPD) combining with water compatible magnetic molecularly imprinted polymers (MMIP) for preconcentration of melamine from milk samples prior high-performance liquid chromatography with UV detection. By employing MMIP as dispersant sorbent matrix interferences could be eliminated completely and the column packing step was interestingly omitted that decreasing in glassware expenditure, labor effort and extraction time which cause improvement of the method performance. In order to investigate the functionality, morphology and magnetic properties of the prepared MMIP, it was fully characterized by FT-IR, VSM, SEM, and TEM. Multivariate optimization was applied as a versatile statistical approach for evaluating the influence of the main variables and their interactions on extraction efficiency. Under optimized conditions, the proposed method exhibited a wide linear response in the concentration range of 250.0-5000.0 μg L-1, satisfactory recoveries for all samples (86.6% ≤), and supreme repeatability (RSD less than 6.3%) were achieved as well. The low limit of detection close to 67.0 μg L-1 implied high ability of proposed method for isolation of melamine from complicate milk sample. These befitting results demonstrated that the developed method is unique in terms of the facility, rapidly and least solvent consumption as well as accurate analysis of melamine at trace levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Strategies of molecular imprinting-based solid-phase extraction prior to chromatographic analysis
Arabi, M., Ostovan, A., Bagheri, A. R., Guo, X., Wang, L., Li, J., Wang, X., Li, B., & Chen, L. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.115923 · Cited by 463
Self-citationMolecularly imprinted polymers-based microextraction techniques
Turiel, E., & Martín-Esteban, A. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.06.016 · Cited by 208
Molecularly imprinted polymers for food applications: A review
Villa, C. C., Sánchez, L. T., Valencia, G. A., Ahmed, S., & Gutiérrez, T. J. (2021) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2021.03.003 · Cited by 191
Farajzadeh, M. A., Abbaspour, M., & Kazemian, R. (2019) · Journal of Chromatography A · doi:10.1016/j.chroma.2019.06.051 · Cited by 56
Magnetic metal organic framework for pre-concentration of ampicillin from cow milk samples
Bagheri, A. R., & Ghaedi, M. (2020) · Journal of Pharmaceutical Analysis · doi:10.1016/j.jpha.2020.02.006 · Cited by 46
Self-citation
Metadata
- Authors
- Gholami, H., Arabi, M., Ghaedi, M., Ostovan, A., & Bagheri, A. R.
- Venue
- Journal of Chromatography A
- Publisher
- Elsevier BV
- Published
- 2019-06
- Volume
- 1594
- Pages
- 13-22
- ISSN
- 0021-9673 (ISSN-L)
- OpenAlex
- W2913336340
- Cited by
- 91
- References
- 0
- FWCI
- 9.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Column packing elimination in matrix solid phase dispersion by using water compatible magnetic molecularly imprinted polymer for recognition of melamine from milk samples. https://app.cochat.ai/papers/10.1016/j.chroma.2019.02.015
- The paper
- Gholami, H., Arabi, M., Ghaedi, M., Ostovan, A., & Bagheri, A. R. (2019). Column packing elimination in matrix solid phase dispersion by using water compatible magnetic molecularly imprinted polymer for recognition of melamine from milk samples. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2019.02.015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.