CoChat

Combination of gel-electromembrane extraction with switchable hydrophilicity solvent-based homogeneous liquid-liquid microextraction followed by gas chromatography for the extraction and determination of antidepressants in human serum, breast milk and wastewater

Behpour, Majid, Nojavan, Saeed, Asadi, Sakine, Shokri, Ali · 2020 · Journal of Chromatography A
Cited by 59

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The current study presents for the first time a combination of the gel electromembrane extraction (GEL-EME) and switchable hydrophilicity solvent-based homogeneous liquid-liquid microextraction (SHS-HLLME) methods which can be used as an efficient hyphenated extraction procedure. This coupled method, which was followed by GC-FID, was applied for quantification of antidepressants (desipramine, clozapine, and citalopram) in biological and wastewater samples. The effective parameters of both GEL-EME and SHS-HLLME procedures were optimized. Using an agarose gel membrane, analytes were extracted from 7.0 mL of the sample solution to 500 µL of the aqueous acceptor solution. The maximum extraction of analytes of interest was obtained under the optimized conditions (pH of acceptor solution, 5.0; pH of gel membrane, 5.0; pH of sample solution, 7.0, voltage value, 30 V; and extraction time, 30 min). Then, the acceptor solution was transferred to the extraction cell and the SHS-HLLME procedure was conducted again under the optimized conditions. Dipropylamine (50 µL) was selected as an extraction solvent. The introduced technique exhibited good linearities with coefficients of determinatin (R2) higher than 0.983 and an acceptable linear range of 5.0-1000 ng/mL. Accordingly, the limit of detection was ≤ 1.0 ng/mL (S/N = 3) for all analytes, and the high enrichment factors were obtained in the range of 178.7-194.8. Moreover, the corresponding repeatability was from 4.0 to 8.7% (n = 3). The proposed method was successfully utilized to determine trace levels of the drugs in human serum, wastewater, and breast milk samples.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.chroma.2020.461041

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 59

Metadata

Authors
Behpour, M., Nojavan, S., Asadi, S., & Shokri, A.
Venue
Journal of Chromatography A
Publisher
Elsevier BV
Published
2020-06
Volume
1621
Pages
461041
ISSN
0021-9673 (ISSN-L)
OpenAlex
W3011134023
Cited by
59
References
2
FWCI
5.32
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Combination of gel-electromembrane extraction with switchable hydrophilicity solvent-based homogeneous liquid-liquid microextraction followed by gas chromatography for the extraction and determination of antidepressants in human serum, breast milk and wastewater. https://app.cochat.ai/papers/10.1016/j.chroma.2020.461041
The paper
Behpour, M., Nojavan, S., Asadi, S., & Shokri, A. (2020). Combination of gel-electromembrane extraction with switchable hydrophilicity solvent-based homogeneous liquid-liquid microextraction followed by gas chromatography for the extraction and determination of antidepressants in human serum, breast milk and wastewater. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2020.461041

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.