Automated quality analysis in continuous downstream processes for small-scale applications
Abstract
Development of integrated, continuous biomanufacturing (ICB) processes brings along the challenge of streamlining the acquisition of data that can be used for process monitoring, product quality testing and process control. Manually performing sample acquisition, preparation, and analysis during process and product development on ICB platforms requires time and labor that diverts attention from the development itself. It also introduces variability in terms of human error in the handling of samples. To address this, a platform for automatic sampling, sample preparation and analysis for use in small-scale biopharmaceutical downstream processes was developed. The automatic quality analysis system (QAS) consisted of an ÄKTA Explorer chromatography system for sample retrieval, storage, and preparation, as well as an Agilent 1260 Infinity II analytical HPLC system for analysis. The ÄKTA Explorer system was fitted with a superloop in which samples could be stored, conditioned, and diluted before being sent to the injection loop of the Agilent system. The Python-based software Orbit, developed at the department of chemical engineering at Lund university, was used to control and create a communication framework for the systems. To demonstrate the QAS in action, a continuous capture chromatography process utilizing periodic counter-current chromatography was set up on an ÄKTA Pure chromatography system to purify the clarified harvest from a bioreactor for monoclonal antibody productio…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Manual sample acquisition and preparation also introduce variability due to human errors in sample handling [39].”
From Current PAT Landscape in the Downstream Processing of Biopharmaceuticals (2025) · cites this paper as [39]
Citations
Cites
Process analytical technology (PAT) for biopharmaceutical products
Rathore, A. S., Bhambure, R., & Ghare, V. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3781-x · Cited by 368
Digital Twins in Pharmaceutical and Biopharmaceutical Manufacturing: A Literature Review
Chen, Y., Yang, O., Sampat, C., Bhalode, P., Ramachandran, R., & Ierapetritou, M. (2020) · Processes · doi:10.3390/pr8091088 · Cited by 278
Goyon, A., Excoffier, M., Janin-Bussat, M.-C., Bobaly, B., Fekete, S., Guillarme, D., & Beck, A. (2017) · Journal of Chromatography B · doi:10.1016/j.jchromb.2017.09.033 · Cited by 227
Bioprocess Control: Current Progress and Future Perspectives
Rathore, A. S., Mishra, S., Nikita, S., & Priyanka, P. (2021) · Life · doi:10.3390/life11060557 · Cited by 141
Opportunities and challenges of real-time release testing in biopharmaceutical manufacturing
Jiang, M., Severson, K. A., Love, J. C., Madden, H., Swann, P., Zang, L., & Braatz, R. D. (2017) · Biotechnology and Bioengineering · doi:10.1002/bit.26383 · Cited by 118
Patel, B. A., Pinto, N. D. S., Gospodarek, A. M., Kilgore, B. R., Goswami, K., Napoli, W. N., Desai, J., Heo, J. H., Panzera, D., Pollard, D. J., et al. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b02228 · Cited by 68
Liu, Y., Zhang, C., Chen, J., Fernandez, J., Vellala, P., Kulkarni, T. A., Aguilar, I., Ritz, D., Lan, K., Patel, P., et al. (2022) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2021.09.011 · Cited by 57
Gomis‐Fons, J., Andersson, N., & Nilsson, B. (2020) · Journal of Chromatography A · doi:10.1016/j.chroma.2020.461055 · Cited by 56
Self-citationModel‐based design and control of a small‐scale integrated continuous end‐to‐end mAb platform
Gomis‐Fons, J., Schwarz, H., Zhang, L., Andersson, N., Nilsson, B., Castan, A., Solbrand, A., Stevenson, J., & Chotteau, V. (2020) · Biotechnology Progress · doi:10.1002/btpr.2995 · Cited by 55
Self-citationIntegrated continuous biomanufacturing on pilot scale for acid‐sensitive monoclonal antibodies
Schwarz, H., Gomis‐Fons, J., Isaksson, M., Scheffel, J., Andersson, N., Andersson, A., Castan, A., Solbrand, A., Hober, S., Nilsson, B., et al. (2022) · Biotechnology and Bioengineering · doi:10.1002/bit.28120 · Cited by 50
Self-citation
Research works printed but not linked: 2
- Millan, 2017, Using the NISTmAb reference standard to demonstrate a simple approach to charge variant analysis, Thermo Fisher Sci.
- Skoglar, 2015, The use of dynamic control in continuous chromatography, Cytiva (General Electric Company)
Cited by
Current PAT Landscape in the Downstream Processing of Biopharmaceuticals
Sathiyapriyan, P., Mukherjee, S., Vogel, T., Essen, L., Boerema, D., Vey, M., & Kalina, U. (2025) · Analytical Science Advances · doi:10.1002/ansa.70013 · Cited by 45
Metadata
- Authors
- Tallvod, S., Espinoza, D., Gomis-Fons, J., Andersson, N., & Nilsson, B.
- Venue
- Journal of Chromatography A
- Publisher
- Elsevier BV
- Published
- 2023-08
- Volume
- 1702
- Pages
- 464085
- ISSN
- 0021-9673
- Cited by
- 11
- References
- 25
- Language
- en
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- creativecommons.org/licenses/by/4.0/ (vor)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated quality analysis in continuous downstream processes for small-scale applications. https://app.cochat.ai/papers/10.1016/j.chroma.2023.464085
- The paper
- Tallvod, S., Espinoza, D., Gomis-Fons, J., Andersson, N., & Nilsson, B. (2023). Automated quality analysis in continuous downstream processes for small-scale applications. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2023.464085
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.