The application of atomic force microscopy in mineral flotation
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
During the past years, atomic force microscopy (AFM) has matured to an indispensable tool to characterize nanomaterials in colloid and interface science. For imaging, a sharp probe mounted near to the end of a cantilever scans over the sample surface providing a high resolution three-dimensional topographic image. In addition, the AFM tip can be used as a force sensor to detect local properties like adhesion, stiffness, charge etc. After the invention of the colloidal probe technique it has also become a major method to measure surface forces. In this review, we highlight the advances in the application of AFM in the field of mineral flotation, such as mineral morphology imaging, water at mineral surface, reagent adsorption, inter-particle force, and bubble-particle interaction. In the coming years, the complementary characterization of chemical composition such as using infrared spectroscopy and Raman spectroscopy for AFM topography imaging and the synchronous measurement of the force and distance involving deformable bubble as a force sensor will further assist the fundamental understanding of flotation mechanism.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Force measurements with the atomic force microscope: Technique, interpretation and applications
Butt, H.-J., Cappella, B., & Kappl, M. (2005) · Surface Science Reports · doi:10.1016/j.surfrep.2005.08.003 · Cited by 4,297
Self-citationFluidity of water confined to subnanometre films
Raviv, U., Laurat, P., & Klein, J. (2001) · Nature · doi:10.1038/35092523 · Cited by 660
Jalili, N., & Laxminarayana, K. (2004) · Mechatronics · doi:10.1016/j.mechatronics.2004.04.005 · Cited by 610
Fukuma, T., Ueda, Y., Yoshioka, S., & Asakawa, H. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.016101 · Cited by 464
Structured and viscous water in subnanometer gaps
Li, T.-D., Gao, J., Szoszkiewicz, R., Landman, U., & Riedo, E. (2007) · Physical Review B · doi:10.1103/physrevb.75.115415 · Cited by 359
Fukuma, T., Reischl, B., Kobayashi, N., Spijker, P., Canova, F. F., Miyazawa, K., & Foster, A. S. (2015) · Physical Review B · doi:10.1103/physrevb.92.155412 · Cited by 126
Stepwise collapse of highly overlapping electrical double layers
Zachariah, Z., Espinosa-Marzal, R. M., Spencer, N. D., & Heuberger, M. P. (2016) · Physical Chemistry Chemical Physics · doi:10.1039/c6cp04222h · Cited by 37
Metadata
- Authors
- Xing, Y., Xu, M., Gui, X., Cao, Y., Babel, B., Rudolph, M., Weber, S., Kappl, M., & Butt, H.-J.
- Venue
- Advances in Colloid and Interface Science
- Publisher
- Elsevier BV
- Published
- 2018-06
- Volume
- 256
- Pages
- 373-392
- ISSN
- 0001-8686 (ISSN-L)
- OpenAlex
- W2790814727
- Cited by
- 178
- References
- 7
- FWCI
- 7.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The application of atomic force microscopy in mineral flotation. https://app.cochat.ai/papers/10.1016/j.cis.2018.01.004
- The paper
- Xing, Y., Xu, M., Gui, X., Cao, Y., Babel, B., Rudolph, M., Weber, S., Kappl, M., & Butt, H.-J. (2018). The application of atomic force microscopy in mineral flotation. Advances in Colloid and Interface Science. https://doi.org/10.1016/j.cis.2018.01.004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.