The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Morphology and microstructural analysis of bioactive-loaded micro/nanocarriers via microscopy techniques; CLSM/SEM/TEM/AFM
Abstract
Efficient characterization of the physicochemical attributes of bioactive-loaded micro/nano-vehicles is crucial for the successful product development. The introduction of outstanding science-based strategies and techniques makes it possible to realize how the characteristics of the formulation ingredients affect the structural and (bio)functional properties of the final bioactive-loaded carriers. The important points to be solved, at a microscopic level, are investigating how the features of the formulation ingredients affect the morphology, surface, size, dispersity, as well as the particulate interactions within bioactive-comprising nano/micro-delivery systems. This review presents a detailed description concerning the application of advanced microscopy techniques, i.e., confocal laser scanning microscopy (CLSM), scanning electron microscopy (SEM), transmission electron microscopy (TEM), and atomic force microscopy (AFM) in characterizing the attributes of nano/microcarriers for the efficient delivery of bioactive compounds. Furthermore, the fundamental principles of these approaches, instrumentation, specific applications, and the strategy to choose the most proper technique for different carriers has been discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transmission Electron Microscopy of Shape-Controlled Nanocrystals and Their Assemblies
Wang, Z. L. (2000) · The Journal of Physical Chemistry B · doi:10.1021/jp993593c · Cited by 2,137
Kuntsche, J., Horst, J. C., & Bunjes, H. (2011) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2011.02.001 · Cited by 363
Klang, V., & Valenta, C. (2011) · Journal of Drug Delivery Science and Technology · doi:10.1016/s1773-2247(11)50006-1 · Cited by 228
Cryoelectron microscopy of liposomes
Frederik, P. M., & Hubert, D. H. W. (2005) · Methods in Enzymology · doi:10.1016/s0076-6879(05)91024-0 · Cited by 121
Cited by
Castillo-Henríquez, L., Alfaro-Aguilar, K., Ugalde-Álvarez, J., Vega-Fernández, L., Montes de Oca-Vásquez, G., & Vega-Baudrit, J. R. (2020) · Nanomaterials · doi:10.3390/nano10091763 · Cited by 444
Formation, antimicrobial activity, and biomedical performance of plant-based nanoparticles: a review
Nguyen, N. T. T., Nguyen, L. M., Nguyen, T. T. T., Nguyen, T. T., Nguyen, D. T. C., & Tran, T. V. (2022) · Environmental Chemistry Letters · doi:10.1007/s10311-022-01425-w · Cited by 175
Metadata
- Authors
- Falsafi, S. R., Rostamabadi, H., Assadpour, E., & Jafari, S. M.
- Venue
- Advances in Colloid and Interface Science
- Publisher
- Elsevier BV
- Published
- 2020-06
- Volume
- 280
- Pages
- 102166
- ISSN
- 0001-8686 (ISSN-L)
- OpenAlex
- W3019916075
- Cited by
- 218
- References
- 4
- FWCI
- 3.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.