A Deep-Learning Algorithm-Enhanced System Integrating Electrocardiograms and Chest X-rays for Diagnosing Aortic Dissection
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
BACKGROUND Chest pain is the most common symptom of aortic dissection (AD), but it is often confused with other prevalent cardiopulmonary diseases. We aimed to develop deep-learning models (DLMs) with ECG and CXR features to detect AD and evaluate their performance. METHODS This study included 43,473 patients in the emergency department (ED) between July 2012 and December 2019 for retrospective DLM development. A development cohort including 49,071 ED records (120 AD-type A and 64 AD-type B) was used to train DLMs for ECG and CXR, and 9,904 independent ED records (40 AD-type A and 34 AD-type B) were used to validate DLM performance. Human-machine competitions of ECG and CXR were conducted. Patient characteristics and laboratory results were used to enhance the diagnostic accuracy. The DLM-enabled AD diagnostic process was prospectively evaluated in 25,885 ED visits. RESULTS The AUCs of the ECG and CXR models were 0.918 and 0.857 for detecting AD in a human-machine competition, respectively, which were better than those of the participating physicians. In the validation cohort, the AUCs of the integrated model were 0.882, 0.960, and 0.813 in all AD, AD-type A, and AD-type B patients, respectively, with a sensitivity of 100.0% and a specificity of 81.7% for AD-type A. In patients with chest pain and D-dimer tests, the DLM could predict more precisely, achieving a positive predictive value of 62.5% in the prospective evaluation. CONCLUSIONS DLMs may serve as decision-supporting tools for AD identification and facilitate differential diagnosis in patients with acute chest pain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
A guide to deep learning in healthcare
Esteva, A., Robicquet, A., Ramsundar, B., Kuleshov, V., DePristo, M., Chou, K., Cui, C., Corrado, G., Thrun, S., & Dean, J. (2019) · Nature Medicine · doi:10.1038/s41591-018-0316-z · Cited by 5,312 · cited 1×
“12 Compared with the traditional machine-learning algorithm with manual feature engineering, deep-learning models (DLMs) can extract features unrecognizable by humans with automatic feature engineering.”
Erbel (2014) · doi:10.1093/eurheartj/ehu281 · Cited by 4,451
Can we open the black box of AI?
Castelvecchi, D. (2016) · Nature · doi:10.1038/538020a · Cited by 1,773 · cited 1×
“26 To understand the AI decisions, we used class-activation mappings to display the focus of the algorithm on ECGs and CXRs (Supplemental Figs.”
Attia, Z. I., Noseworthy, P. A., Lopez-Jimenez, F., Asirvatham, S. J., Deshmukh, A. J., Gersh, B. J., Carter, R. E., Yao, X., Rabinstein, A. A., Erickson, B. J., et al. (2019) · The Lancet · doi:10.1016/s0140-6736(19)31721-0 · Cited by 1,613 · cited 1×
“14,15 AI algorithms have also shown remarkable progress in image-recognition tasks with broad applications.”
Rajpurkar, P., Irvin, J., Ball, R. L., Zhu, K., Yang, B., Mehta, H., Duan, T., Ding, D., Bagul, A., Langlotz, C. P., et al. (2018) · PLOS Medicine · doi:10.1371/journal.pmed.1002686 · Cited by 1,449
Lin, C.-S., Lin, C., Fang, W.-H., Hsu, C.-J., Chen, S.-J., Huang, K.-H., Lin, W.-S., Tsai, C.-S., Kuo, C.-C., Chau, T., et al. (2020) · JMIR Medical Informatics · doi:10.2196/15931 · Cited by 109
Self-citation
Cited by
Lin, C., Chau, T., Lin, C.-S., Shang, H.-S., Fang, W.-H., Lee, D.-J., Lee, C.-C., Tsai, S.-H., Wang, C.-H., & Lin, S.-H. (2022) · npj Digital Medicine · doi:10.1038/s41746-021-00550-0 · Cited by 62
Self-citationLin, C., Chen, C.-C., Chau, T., Lin, C.-S., Tsai, S.-H., Lee, D.-J., Lee, C.-C., Shang, H.-S., & Lin, S.-H. (2022) · Clinica Chimica Acta · doi:10.1016/j.cca.2022.09.021 · Cited by 10
Self-citationLin, C., Kuo, F.-C., Chau, T., Shih, J.-H., Lin, C.-S., Chen, C.-C., Lee, C.-C., & Lin, S.-H. (2024) · Communications Medicine · doi:10.1038/s43856-024-00472-4 · Cited by 8
Self-citationYang, C.-C., Lin, C.-S., Lin, C., Liu, W.-T., Lai, Z.-Y., & Chuang, Y.-J. (2026) · Internal and Emergency Medicine · doi:10.1007/s11739-025-04209-6 · Cited by 3
Self-citation
Metadata
- Authors
- Liu, W.-T., Lin, C.-S., Tsao, T.-P., Lee, C.-C., Cheng, C.-C., Chen, J.-T., Tsai, C.-S., Lin, W.-S., & Lin, C.
- Venue
- Canadian Journal of Cardiology
- Publisher
- Elsevier BV
- Published
- 2022-02
- Volume
- 38
- Issue
- 2
- Pages
- 160-168
- ISSN
- 0828-282X (ISSN-L)
- OpenAlex
- W3204611206
- Cited by
- 46
- References
- 7
- FWCI
- 4.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Deep-Learning Algorithm-Enhanced System Integrating Electrocardiograms and Chest X-rays for Diagnosing Aortic Dissection. https://app.cochat.ai/papers/10.1016/j.cjca.2021.09.028
- The paper
- Liu, W.-T., Lin, C.-S., Tsao, T.-P., Lee, C.-C., Cheng, C.-C., Chen, J.-T., Tsai, C.-S., Lin, W.-S., & Lin, C. (2022). A Deep-Learning Algorithm-Enhanced System Integrating Electrocardiograms and Chest X-rays for Diagnosing Aortic Dissection. Canadian Journal of Cardiology. https://doi.org/10.1016/j.cjca.2021.09.028
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.