Standards of instrumentation of EMG
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Standardization of Electromyography (EMG) instrumentation is of particular importance to ensure high quality recordings. This consensus report on "Standards of Instrumentation of EMG" is an update and extension of the earlier IFCN Guidelines published in 1999. First, a panel of experts in different fields from different geographical distributions was invited to submit a section on their particular interest and expertise. Then, the merged document was circulated for comments and edits until a consensus emerged. The first sections in this document cover technical aspects such as instrumentation, EMG hardware and software including amplifiers and filters, digital signal analysis and instrumentation settings. Other sections cover the topics such as temporary storage, trigger and delay line, averaging, electrode types, stimulation techniques for optimal and standardised EMG examinations, and the artefacts electromyographers may face and safety rules they should follow. Finally, storage of data and databases, report generators and external communication are summarized.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rossini, P. M., Burke, D., Chen, R., Cohen, L. G., Daskalakis, Z., Di Iorio, R., Di Lazzaro, V., Ferreri, F., Fitzgerald, P. B., George, M. S., et al. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.02.001 · Cited by 2,753 · cited 2×
“, (Rossini et al., 2015)), or when recording the H reflex from a muscle from which it”
BackgroundSelf-citationWhat is the Bereitschaftspotential?
Shibasaki, H., & Hallett, M. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.04.025 · Cited by 1,169
Evoked action potentials and conduction velocity in human sensory nerves
Buchthal, F., & Rosenfalck, A. (1966) · Brain Research · doi:10.1016/0006-8993(66)90056-4 · Cited by 756 · cited 1×
“Sensory nerve action potentials (SNAPs) may be recorded with surface electrodes (or near-nerve needle electrodes (Buchthal and Rosenfalck, 1966)) but with both techniques the SNAP is often difficult to define in single sweeps; somatosensory evoked potentials (SSEPs) are always so.”
BackgroundThe Circuitry of the Human Spinal Cord: Its Role in Motor Control and Movement Disorders
Pierrot-Deseilligny, E., & Burke, D. (2005) · Cambridge University Press eBooks · doi:10.1017/cbo9780511545047 · Cited by 486
Self-citationSurface myoelectric signal cross-talk among muscles of the leg
De Luca, C. J., & Merletti, R. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90169-1 · Cited by 339
Electrophysiological studies of myoclonus
Shibasaki, H., & Hallett, M. (2005) · Muscle & Nerve · doi:10.1002/mus.20234 · Cited by 302
The Circuitry of the Human Spinal Cord : Its Role in Motor Control and Movement Disorders
Pierrot-Deseilligny, E., & Burke, D. J. (2009) · Cited by 273
Self-citationElectromyography: Some Methodological Problems and Issues
Türker, K. S. (1993) · Physical Therapy · doi:10.1093/ptj/73.10.698 · Cited by 268 · cited 3×
“Filtering is not useful for cross-talk, since desired and cross talk signals have similar frequency ranges (Türker, 1993).”
BackgroundStandards for quantification of EMG and neurography
Stålberg, E., van Dijk, H., Falck, B., Kimura, J., Neuwirth, C., Pitt, M., Podnar, S., Rubin, D. I., Rutkove, S., Sanders, D. B., et al. (2019) · Clinical Neurophysiology · doi:10.1016/j.clinph.2019.05.008 · Cited by 254
Self-citationMinimizing Electrode Motion Artifact by Skin Abrasion
Tam, H., & Webster, J. G. (1977) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1977.326117 · Cited by 220
Martinez‐Valdes, E., Negro, F., Laine, C. M., Falla, D., Mayer, F., & Farina, D. (2017) · The Journal of Physiology · doi:10.1113/jp273662 · Cited by 215 · cited 1×
“, 2019), sports medicine (Martinez-Valdes et al., 2017) and rehabilitation (Gallina et al.”
BackgroundReducing Motion Artifacts and Interference in Biopotential Recording
Webster, J. G. (1984) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1984.325244 · Cited by 181 · cited 2×
“The goal of the recording system is the exact reproduction of the physiological signals generated in muscle cells and peripheral nerves, but artefacts are unavoidable (Webster, 1984).”
BackgroundClinical uses of H reflexes of upper and lower limb muscles
Burke, D. (2016) · Clinical Neurophysiology Practice · doi:10.1016/j.cnp.2016.02.003 · Cited by 172 · cited 2×
“cannot normally be recorded at rest (such as tibialis anterior, the thenar muscles, extensor carpi radialis; see (Burke, 2016).”
BackgroundSelf-citationMcGill, K. C., Cummins, K. L., Dorfman, L. J., Berlizot, B. B., Luetkemeyer, K., Nishimura, D. G., & Widrow, B. (1982) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1982.325019 · Cited by 143 · cited 1×
“A large surface ground electrode or felt band ground electrode is recommended, positioned close to the recording electrode (between stimulator and recording electrode in conduction studies), not overlying electrically active surfaces like as muscle, and with a low electrical resistance (<3-5kOhms)(Türker, 1993; McGill…”
BackgroundElectrical Impedance Myography and Its Applications in Neuromuscular Disorders
Sanchez, B., & Rutkove, S. B. (2016) · Neurotherapeutics · doi:10.1007/s13311-016-0491-x · Cited by 140
Self-citationReducing skin potential motion artefact by skin abrasion
Burbank, D. P., & Webster, J. G. (1978) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442929 · Cited by 130
The utility of interference pattern analysis
Fuglsang‐Frederiksen, A. (2000) · Muscle & Nerve · doi:10.1002/(sici)1097-4598(200001)23:1<18::aid-mus4>3.0.co;2-b · Cited by 113
Self-citationIatrogenic complications and risks of nerve conduction studies and needle electromyography
Alshekhlee, A., Shapiro, B. E., & Preston, D. C. (2003) · Muscle & Nerve · doi:10.1002/mus.10315 · Cited by 111 · cited 1×
“Some authors have suggested in these patients that proximal NCS or NCS in the ipsilateral extremity should not be performed because the catheters in the internal jugular or subclavian veins extend to the heart (Al-Shekhlee et al., 2003) while others did not show any influence of NCS on electrocardiographic monitoring…”
BackgroundCurrent status on electrodiagnostic standards and guidelines in neuromuscular disorders
Fuglsang‐Frederiksen, A., & Pugdahl, K. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.06.025 · Cited by 109 · cited 1×
“Evidence-based documentation is, at present, sparse in electrodiagnostic medicine (Fuglsang-Frederiksen and Pugdahl, 2011).”
BackgroundSelf-citationThe circuitry of the human spinal cord: Its role in motor control and movement disorders
Valls‐Solé, J. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.01.016 · Cited by 102
Diagnostic yield of noninvasive high spatial resolution electromyography in neuromuscular diseases
Huppertz, H.-J., Disselhorst-klug, C., Silny, J., Rau, G., & Heimann, G. (1997) · Muscle & Nerve · doi:10.1002/(sici)1097-4598(199711)20:11<1360::aid-mus3>3.0.co;2-8 · Cited by 72 · cited 2×
“, 2004) and disorders (Huppertz et al., 1997) and pathological changes have been shown at the motor unit level in neurogenic and myopathic muscles.”
BackgroundSurface electromyography using electrode arrays: A study of motor neuron disease
Wood, S. M., Jarratt, J. A., Barker, A. T., & Brown, B. H. (2001) · Muscle & Nerve · doi:10.1002/1097-4598(200102)24:2<223::aid-mus70>3.0.co;2-7 · Cited by 45 · cited 2×
“HD-sEMG has been shown to be beneficial for the assessment of different clinical conditions including motor neuron disorders (Wood et al., 2001; Drost et al., 2004) and disorders (Huppertz et al.”
BackgroundSafety and pain in electrodiagnostic studies
London, Z. N. (2016) · Muscle & Nerve · doi:10.1002/mus.25421 · Cited by 43 · cited 6×
“In a recent review, no precautions were recommended during needle EMG examinations in patients on warfarin therapy if INR<3.0 or on antiplatelet medication (London, 2017).”
BackgroundInfluentialDrost, G., Stegeman, D. F., Schillings, M. L., Horemans, H. L. D., Janssen, H. M. H. A., Massa, M., Nollet, F., & Zwarts, M. J. (2004) · Muscle & Nerve · doi:10.1002/mus.20104 · Cited by 38 · cited 2×
“HD-sEMG has been shown to be beneficial for the assessment of different clinical conditions including motor neuron disorders (Wood et al., 2001; Drost et al., 2004) and disorders (Huppertz et al.”
BackgroundA delay line to record random action potentials
Nissen-Petersen, H., Guld, C., & Buchthal, F. (1969) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(69)90040-6 · Cited by 37 · cited 1×
“The sweep is triggered by the potential in real time, but the display is delayed by the preset interval (Kimura et al., 1988; Czekajewski et al., 1969; Nissen-Petersen et al., 1969).”
BackgroundRecording characteristics of electrical impedance-electromyography needle electrodes
Kwon, H., Cristina, J. F. D., Rutkove, S. B., & Sanchez, B. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aabb8c · Cited by 35 · cited 1×
“A final class of needles include those that can be used for electrical impedance myography, either alone or in combination with standard monopolar EMG electrode (Kwon et al., 2018).”
BackgroundSelf-citationReport of the committee on EMG instrumentation
Guld, C., Rosenfalck, A. M., & Willison, R. G. (1970) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(70)90233-6 · Cited by 34 · cited 1×
“Reports on electromyographic instrumentation have been published previously (Guld et al., 1970; Guld et al., 1974; Guld et al., 1983; Bischoff et al., 1999).”
BackgroundKural, M. A., Karlsson, P., Pugdahl, K., Isak, B., Fuglsang‐Frederiksen, A., & Tankişi, H. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2017.06.031 · Cited by 32 · cited 1×
“Monopolar needles can also be used as recording electrodes for sensory nerve action potentials in the near-nerve technique (Kural et al., 2017) and as stimulation electrodes (e.”
BackgroundSelf-citationGallina, A., Pollock, C. L., Vieira, T., Ivanova, T. D., & Garland, S. J. (2015) · Gait & Posture · doi:10.1016/j.gaitpost.2015.11.015 · Cited by 20 · cited 1×
“, 2017) and rehabilitation (Gallina et al., 2016) rather than the primary diagnosis of neuromuscular disorders.”
BackgroundExcitability tests using high-density surface-EMG: A novel approach to studying single motor units
Sleutjes, B. T. H. M., Drenthen, J., Boskovic, E., van Schelven, L. J., Kovalchuk, M. O., Lumens, P. G. E., van den Berg, L. H., & Franssen, H. (2018) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.04.754 · Cited by 12 · cited 1×
“Recent research has also mostly focused on physiological studies (Sleutjes et al., 2018; Lapatki et al., 2019), sports medicine (Martinez-Valdes et al.”
BackgroundLapatki, B. G., Eiglsperger, U., Schindler, H. J., Radeke, J., Holobar, A., & van Dijk, J. P. (2019) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.12.008 · Cited by 11 · cited 1×
“Recent research has also mostly focused on physiological studies (Sleutjes et al., 2018; Lapatki et al., 2019), sports medicine (Martinez-Valdes et al.”
BackgroundLee, I., & Kushlaf, H. A. (2018) · Muscle & Nerve · doi:10.1002/mus.26119 · Cited by 8
Movement artefact suppressor during ECG monitoring
Klijn, J., & Kloprogge, M. J. G. M. (1974) · Cardiovascular Research · doi:10.1093/cvr/8.1.149 · Cited by 7
Cited by
McManus, L., De Vito, G., & Lowery, M. M. (2020) · Frontiers in Neurology · doi:10.3389/fneur.2020.576729 · Cited by 192
“(55), Gitter and Stolov (56), Gitter and Stolov (57), and Merletti and Cerone (58).”
BackgroundPhenomic studies on diseases: potential and challenges
Ying, W. (2023) · Phenomics · doi:10.1007/s43657-022-00089-4 · Cited by 96
Metadata
- Authors
- Tankisi, H., Burke, D., Cui, L., de Carvalho, M., Kuwabara, S., Nandedkar, S. D., Rutkove, S., Stålberg, E., van Putten, M. J. A. M., & Fuglsang-Frederiksen, A.
- Venue
- Clinical Neurophysiology
- Publisher
- Elsevier BV
- Published
- 2020-01
- Volume
- 131
- Issue
- 1
- Pages
- 243-258
- ISSN
- 1388-2457 (ISSN-L)
- OpenAlex
- W2987126293
- Cited by
- 205
- References
- 33
- FWCI
- 6.30
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.