Multifrequency bioelectrical impedance analysis and bioimpedance spectroscopy for monitoring fluid and body cell mass changes after gastric bypass surgery
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Summary Background & aims There is a growing need for clinically applicable body composition assessment tools for extremely obese individuals. The objective of this research was to evaluate several bio impedance techniques for monitoring changes in fluid, particularly intracellular water (reflecting body cell mass) after bariatric surgery. Design Fifteen extremely obese women (body mass index: 48.9 ±7.0 kg/m2; age: 48 ±9 years) were assessed before (baseline; T1), and approximately 6 weeks after gastric bypass surgery (T2) by several multifrequency bioelectrical impedance analysis approaches (MFBIA; QuadScan 4000), a bioimpedance spectroscopy device (BIS; Hydra 4200), and multiple dilution. Results BIS provided intracellular water estimates that were comparable to criterion, based on mean comparisons, at both time points (T1: criterion: 24.2 ±3.1 L, BIS: 24.0 ± 3.7 L; T2: criterion: 20.6 ± 3.7 L, BIS: 19.7 ± 3.2 L). MFBIA (with Deurenberg equations) provided comparable measures to criterion only at T2 (criterion: 20.3 ± 3.7 L, MFBIA: 20.6 ± 2.7 L). Both MFBIA (with QuadScan proprietary equations) and BIS produced estimates of intracellular water change that were comparable to dilution. There was substantial variability in individual volume measures. Conclusions Although MFBIA and BIS hold promise as convenient techniques for assessing fluid changes, individual variability in measurements makes them impractical for assessment of extremely obese patients in the clinical setting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Bioelectrical impedance analysis—part II: utilization in clinical practice
Kyle, U. G., Bosaeus, I., De Lorenzo, A. D., Deurenberg, P., Elia, M., Manuel Gómez, J., Lilienthal Heitmann, B., Kent-Smith, L., Melchior, J.-C., Pirlich, M., et al. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.09.012 · Cited by 2,350
Validation of tetrapolar bioelectrical impedance method to assess human body composition
Lukaski, H. C., Bolonchuk, W. W., Hall, C. B., & Siders, W. A. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.4.1327 · Cited by 1,370
Cited by
Bioelectrical Impedance Methods for Noninvasive Health Monitoring: A Review
Bera, T. K. (2014) · Journal of Medical Engineering · doi:10.1155/2014/381251 · Cited by 407
Bioimpedance at the Bedside: Current Applications, Limitations, and Opportunities
Mulasi, U., Kuchnia, A. J., Cole, A. J., & Earthman, C. P. (2015) · Nutrition in Clinical Practice · doi:10.1177/0884533614568155 · Cited by 337
Self-citationLukaski, H. C. (2013) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2012.149 · Cited by 303
Earthman, C. P. (2015) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607115595227 · Cited by 234
“One might choose to do this to minimize the possibility of making a type II error (ie, to avoid the error of falsely accepting the null hypothesis of no difference between the 2 methods).(49) One reasonable approach to minimize erroneous conclusions from a paired t test is to apply it in combination with linear regres…”
BackgroundSelf-citationLukaski, H. C., Vega Diaz, N., Talluri, A., & Nescolarde, L. (2019) · Nutrients · doi:10.3390/nu11040809 · Cited by 168
Metadata
- Authors
- Mager, J. R., Sibley, S. D., Beckman, T. R., Kellogg, T. A., & Earthman, C. P.
- Venue
- Clinical Nutrition
- Publisher
- Elsevier BV
- Published
- 2008-12
- Volume
- 27
- Issue
- 6
- Pages
- 832-841
- ISSN
- 0261-5614 (ISSN-L)
- OpenAlex
- W2066070422
- Cited by
- 53
- References
- 3
- FWCI
- 1.81
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.