Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 311

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Antimicrobial susceptibility testing of colistin – evaluation of seven commercial MIC products against standard broth microdilution for Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa, and Acinetobacter spp.

Open access
Matuschek, E., Åhman, J., Webster, C., Kahlmeter, G. · 2018 · Clinical Microbiology and Infection

Abstract

OBJECTIVE Both EUCAST and CLSI recommend broth microdilution (BMD) for antimicrobial susceptibility testing of colistin, but BMD is rarely used in routine microbiology laboratories. The objective of this study was to evaluate five commercially available BMD products and two brands of gradient tests for colistin MIC determination using BMD according to ISO standard 20776-1 as reference. METHODS Colistin MIC determination was performed according to the manufacturer's instructions on five commercially available BMD products (Sensititre, MICRONAUT-S, MICRONAUT MIC-Strip, SensiTest, and UMIC) and two gradient tests (Etest and MIC Test Strip). Colistin reference MICs were determined using frozen panels according to ISO standard 20776-1. An international collection of Gram-negative bacteria (n=75) with varying levels of colistin susceptibility was tested. RESULTS The colistin BMD products correlated well with reference tests, in particular for Sensititre and the two MICRONAUT products (essential agreement ≥96%: 66/69 (96%, CI 88-99%), 72/75 (96%, CI 88-99%) and 74/75 (99%, CI 92-100%)). The results were somewhat poorer for the BMD products SensiTest and UMIC: EA 88% (51/58, CI 77-95%) and 82% (61/74, CI 72-89%), respectively), and considerably poorer for the gradient tests (EA 43-71% depending on gradient test and Mueller-Hinton agar manufacturer). The gradient tests generally underestimated colistin MICs, resulting in a significant number of false susceptible results (9-18 of total 75 tests, compared with 1-3 for the BMD products). CONCLUSIONS Based on the results of this study, we advise laboratories not to trust gradient tests for colistin susceptibility testing and to use broth microdilution methods for this purpose. There are several commercial broth microdilution tests available and in principle they perform well.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.cmi.2017.11.020

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 311

Metadata

Authors
Matuschek, E., Åhman, J., Webster, C., & Kahlmeter, G.
Venue
Clinical Microbiology and Infection
Publisher
Elsevier BV
Published
2018-08
Volume
24
Issue
8
Pages
865-870
ISSN
1198-743X (ISSN-L)
OpenAlex
W2773164014
Cited by
311
References
5
FWCI
19.62
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.