A hierarchical method based on weighted extreme gradient boosting in ECG heartbeat classification
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
BACKGROUND AND OBJECTIVE Electrocardiogram (ECG) is a useful tool for detecting heart disease. Automated ECG diagnosis allows for heart monitoring on small devices, especially on wearable devices. In order to recognize arrhythmias automatically, accurate classification method for electrocardiogram (ECG) heartbeats was studied in this paper. METHODS Based on weighted extreme gradient boosting (XGBoost), a hierarchical classification method is proposed. A large number of features from 6 categories are extracted from the preprocessed heartbeats. Then recursive feature elimination is used for selecting features. Afterwards, a hierarchical classifier is constructed in classification stage. The hierarchical classifier is composed of threshold and XGBoost classifiers. And the XGBoost classifiers are improved with weights. RESULTS The method was applied to an inter-patient experiment conforming AAMI standard. The obtained sensitivities for normal (N), supraventricular (S), ventricular (V), fusion (F), and Unknown beats (Q) were 92.1%, 91.7%, 95.1%, and 61.6%. Positive predictive values of 99.5%, 46.2%, 88.1%, and 15.2% were also provided for the four classes. CONCLUSIONS XGBoost was improved and firstly introduced in single heartbeat classification. A comparison showed the effectiveness of the novel method. The method was more suitable for clinical application as both high positive predictive value for N class and high sensitivities for abnormal classes were provided.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Greedy function approximation: A gradient boosting machine
Friedman, J. H. (2001) · The Annals of Statistics · doi:10.1214/aos/1013203451 · Cited by 30,731
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
XGBoost: A Scalable Tree Boosting System
Chen, T., & Guestrin, C. (2016) · arXiv · doi:10.48550/arxiv.1603.02754 · Cited by 7,104
Zheng, H., Yuan, J., & Chen, L. (2017) · Energies · doi:10.3390/en10081168 · Cited by 635
Cited by
Rieg, T., Frick, J., Baumgartl, H., & Buettner, R. (2020) · PLOS ONE · doi:10.1371/journal.pone.0243615 · Cited by 34
Metadata
- Authors
- Shi, H., Wang, H., Huang, Y., Zhao, L., Qin, C., & Liu, C.
- Venue
- Computer Methods and Programs in Biomedicine
- Publisher
- Elsevier BV
- Published
- 2019-04
- Volume
- 171
- Pages
- 1-10
- ISSN
- 0169-2607 (ISSN-L)
- OpenAlex
- W2916066245
- Cited by
- 162
- References
- 4
- FWCI
- 12.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.