Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 187

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Deep learning algorithms for detection of diabetic retinopathy in retinal fundus photographs: A systematic review and meta-analysis

Islam, Md Mohaimenul, Yang, Hsuan-Chia, Poly, Tahmina Nasrin, Jian, Wen-Shan, (Jack) Li, Yu-Chuan · 2020 · Computer Methods and Programs in Biomedicine

Abstract

BACKGROUND Diabetic retinopathy (DR) is one of the leading causes of blindness globally. Earlier detection and timely treatment of DR are desirable to reduce the incidence and progression of vision loss. Currently, deep learning (DL) approaches have offered better performance in detecting DR from retinal fundus images. We, therefore, performed a systematic review with a meta-analysis of relevant studies to quantify the performance of DL algorithms for detecting DR. METHODS A systematic literature search on EMBASE, PubMed, Google Scholar, Scopus was performed between January 1, 2000, and March 31, 2019. The search strategy was based on the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) reporting guidelines, and DL-based study design was mandatory for articles inclusion. Two independent authors screened abstracts and titles against inclusion and exclusion criteria. Data were extracted by two authors independently using a standard form and the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool was used for the risk of bias and applicability assessment. RESULTS Twenty-three studies were included in the systematic review; 20 studies met inclusion criteria for the meta-analysis. The pooled area under the receiving operating curve (AUROC) of DR was 0.97 (95%CI: 0.95-0.98), sensitivity was 0.83 (95%CI: 0.83-0.83), and specificity was 0.92 (95%CI: 0.92-0.92). The positive- and negative-likelihood ratio were 14.11 (95%CI: 9.91-20.07), and 0.10 (95%CI: 0.07-0.16), respectively. Moreover, the diagnostic odds ratio for DL models was 136.83 (95%CI: 79.03-236.93). All the studies provided a DR-grading scale, a human grader (e.g. trained caregivers, ophthalmologists) as a reference standard. CONCLUSION The findings of our study showed that DL algorithms had high sensitivity and specificity for detecting referable DR from retinal fundus photographs. Applying a DL-based automated tool of assessing DR from color fundus images could provide an alternative solution to reduce misdiagnosis and improve workflow. A DL-based automated tool offers substantial benefits to reduce screening costs, accessibility to healthcare and ameliorate earlier treatments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.cmpb.2020.105320

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 187

Metadata

Authors
Islam, M. M., Yang, H.-C., Poly, T. N., Jian, W.-S., & (Jack) Li, Y.-C.
Venue
Computer Methods and Programs in Biomedicine
Publisher
Elsevier BV
Published
2020-07
Volume
191
Pages
105320
ISSN
0169-2607 (ISSN-L)
OpenAlex
W2999301272
Cited by
187
References
10
FWCI
5.04
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Deep learning algorithms for detection of diabetic retinopathy in retinal fundus photographs: A systematic review and meta-analysis. https://app.cochat.ai/papers/10.1016/j.cmpb.2020.105320
The paper
Islam, M. M., Yang, H.-C., Poly, T. N., Jian, W.-S., & (Jack) Li, Y.-C. (2020). Deep learning algorithms for detection of diabetic retinopathy in retinal fundus photographs: A systematic review and meta-analysis. Computer Methods and Programs in Biomedicine. https://doi.org/10.1016/j.cmpb.2020.105320

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.