The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Deep learning algorithms for detection of diabetic retinopathy in retinal fundus photographs: A systematic review and meta-analysis
Abstract
BACKGROUND Diabetic retinopathy (DR) is one of the leading causes of blindness globally. Earlier detection and timely treatment of DR are desirable to reduce the incidence and progression of vision loss. Currently, deep learning (DL) approaches have offered better performance in detecting DR from retinal fundus images. We, therefore, performed a systematic review with a meta-analysis of relevant studies to quantify the performance of DL algorithms for detecting DR. METHODS A systematic literature search on EMBASE, PubMed, Google Scholar, Scopus was performed between January 1, 2000, and March 31, 2019. The search strategy was based on the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) reporting guidelines, and DL-based study design was mandatory for articles inclusion. Two independent authors screened abstracts and titles against inclusion and exclusion criteria. Data were extracted by two authors independently using a standard form and the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool was used for the risk of bias and applicability assessment. RESULTS Twenty-three studies were included in the systematic review; 20 studies met inclusion criteria for the meta-analysis. The pooled area under the receiving operating curve (AUROC) of DR was 0.97 (95%CI: 0.95-0.98), sensitivity was 0.83 (95%CI: 0.83-0.83), and specificity was 0.92 (95%CI: 0.92-0.92). The positive- and negative-likelihood ratio were 14.11 (95%CI: 9.91-20.07), and 0.10 (95%CI: 0.07-0.16), respectively. Moreover, the diagnostic odds ratio for DL models was 136.83 (95%CI: 79.03-236.93). All the studies provided a DR-grading scale, a human grader (e.g. trained caregivers, ophthalmologists) as a reference standard. CONCLUSION The findings of our study showed that DL algorithms had high sensitivity and specificity for detecting referable DR from retinal fundus photographs. Applying a DL-based automated tool of assessing DR from color fundus images could provide an alternative solution to reduce misdiagnosis and improve workflow. A DL-based automated tool offers substantial benefits to reduce screening costs, accessibility to healthcare and ameliorate earlier treatments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ImageNet classification with deep convolutional neural networks
Krizhevsky, A., Sutskever, I., & Hinton, G. E. (2017) · Communications of the ACM · doi:10.1145/3065386 · Cited by 112,155
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
The perceptron: A probabilistic model for information storage and organization in the brain.
Rosenblatt, F. (1958) · Psychological Review · doi:10.1037/h0042519 · Cited by 12,280
Ting, D. S. W., Cheung, C. Y.-L., Lim, G., Tan, G. S. W., Quang, N. D., Gan, A., Hamzah, H., Garcia-Franco, R., San Yeo, I. Y., Lee, S. Y., et al. (2017) · JAMA · doi:10.1001/jama.2017.18152 · Cited by 2,402
Abràmoff, M. D., Lou, Y., Erginay, A., Clarida, W., Amelon, R., Folk, J. C., & Niemeijer, M. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19964 · Cited by 1,101
Guidelines on Diabetic Eye Care
Wong, T. Y., Sun, J., Kawasaki, R., Ruamviboonsuk, P., Gupta, N., Lansingh, V. C., Maia, M., Mathenge, W., Moreker, S., Muqit, M. M. K., et al. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2018.04.007 · Cited by 839
Brown, J. M., Campbell, J. P., Beers, A., Chang, K., Ostmo, S., Chan, R. V. P., Dy, J., Erdogmus, D., Ioannidis, S., Kalpathy-Cramer, J., et al. (2018) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2018.1934 · Cited by 657
Prediction of sepsis patients using machine learning approach: a meta-analysis
Islam, M. M., Nasrin, T., Walther, B. A., Wu, C.-C., Yang, H.-C., & Li, Y.-C. (2019) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2018.12.027 · Cited by 259
Self-citationLi, Z., Keel, S., Liu, C., He, Y., Meng, W., Scheetz, J., Lee, P. Y., Shaw, J., Ting, D., Wong, T. Y., et al. (2018) · Diabetes Care · doi:10.2337/dc18-0147 · Cited by 255
Cited by
A survey on deep learning in medicine: Why, how and when?
Piccialli, F., Somma, V. D., Giampaolo, F., Cuomo, S., & Fortino, G. (2021) · Information Fusion · doi:10.1016/j.inffus.2020.09.006 · Cited by 348
Deep learning for diabetic retinopathy detection and classification based on fundus images: A review
Tsiknakis, N., Theodoropoulos, D., Manikis, G., Ktistakis, E., Boutsora, O., Berto, A., Scarpa, F., Scarpa, A., Fotiadis, D. I., & Marias, K. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.104599 · Cited by 328
Diabetic retinopathy detection and classification using capsule networks
Kalyani, G., Janakiramaiah, B., Karuna, A., & Prasad, L. V. N. (2023) · Complex & Intelligent Systems · doi:10.1007/s40747-021-00318-9 · Cited by 297
Jayakumar, S., Sounderajah, V., Normahani, P., Harling, L., Markar, S. R., Ashrafian, H., & Darzi, A. (2022) · npj Digital Medicine · doi:10.1038/s41746-021-00544-y · Cited by 110
Wu, J.-H., Liu, T. Y. A., Hsu, W.-T., Ho, J. H.-C., & Lee, C.-C. (2021) · Journal of Medical Internet Research · doi:10.2196/23863 · Cited by 108
Metadata
- Authors
- Islam, M. M., Yang, H.-C., Poly, T. N., Jian, W.-S., & (Jack) Li, Y.-C.
- Venue
- Computer Methods and Programs in Biomedicine
- Publisher
- Elsevier BV
- Published
- 2020-07
- Volume
- 191
- Pages
- 105320
- ISSN
- 0169-2607 (ISSN-L)
- OpenAlex
- W2999301272
- Cited by
- 187
- References
- 10
- FWCI
- 5.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Deep learning algorithms for detection of diabetic retinopathy in retinal fundus photographs: A systematic review and meta-analysis. https://app.cochat.ai/papers/10.1016/j.cmpb.2020.105320
- The paper
- Islam, M. M., Yang, H.-C., Poly, T. N., Jian, W.-S., & (Jack) Li, Y.-C. (2020). Deep learning algorithms for detection of diabetic retinopathy in retinal fundus photographs: A systematic review and meta-analysis. Computer Methods and Programs in Biomedicine. https://doi.org/10.1016/j.cmpb.2020.105320
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.