CoChat

Uncertainty quantification in DenseNet model using myocardial infarction ECG signals

Open access
Jahmunah, V., Ng, E.Y.K., Tan, Ru- San, Oh, Shu Lih, Acharya, U. Rajendra · 2023 · Computer Methods and Programs in Biomedicine
Cited by 64

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

BACKGROUND AND OBJECTIVE Myocardial infarction (MI) is a life-threatening condition diagnosed acutely on the electrocardiogram (ECG). Several errors, such as noise, can impair the prediction of automated ECG diagnosis. Therefore, quantification and communication of model uncertainty are essential for reliable MI diagnosis. METHODS A Dirichlet DenseNet model that could analyze out-of-distribution data and detect misclassification of MI and normal ECG signals was developed. The DenseNet model was first trained with the pre-processed MI ECG signals (from the best lead V6) acquired from the Physikalisch-Technische Bundesanstalt (PTB) database, using the reverse Kullback-Leibler (KL) divergence loss. The model was then tested with newly synthesized ECG signals with added em and ma noise samples. Predictive entropy was used as an uncertainty measure to determine the misclassification of normal and MI signals. Model performance was evaluated using four uncertainty metrics: uncertainty sensitivity (UNSE), uncertainty specificity (UNSP), uncertainty accuracy (UNAC), and uncertainty precision (UNPR); the classification threshold was set at 0.3. RESULTS The UNSE of the DenseNet model was low but increased over the studied decremental noise range (-6 to 24 dB), indicating that the model grew more confident in classifying the signals as they got less noisy. The model became more certain in its predictions from SNR values of 12 dB and 18 dB onwards, yielding UNAC values of 80% and 82.4% for em and ma noise signals, respectively. UNSP and UNPR values were close to 100% for em and ma noise signals, indicating that the model was self-aware of what it knew and didn't. CONCLUSION Through this work, it has been established that the model is reliable as it was able to convey when it was not confident in the diagnostic information it was presenting. Thus, the model is trustworthy and can be used in healthcare applications, such as the emergency diagnosis of MI on ECGs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.cmpb.2022.107308

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 64

Metadata

Authors
Jahmunah, V., Ng, E. Y. K., Tan, R. S., Oh, S. L., & Acharya, U. R.
Venue
Computer Methods and Programs in Biomedicine
Publisher
Elsevier BV
Published
2023-02
Volume
229
Pages
107308
ISSN
0169-2607 (ISSN-L)
OpenAlex
W4311989254
Cited by
64
References
6
FWCI
8.63
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Uncertainty quantification in DenseNet model using myocardial infarction ECG signals. https://app.cochat.ai/papers/10.1016/j.cmpb.2022.107308
The paper
Jahmunah, V., Ng, E. Y. K., Tan, R. S., Oh, S. L., & Acharya, U. R. (2023). Uncertainty quantification in DenseNet model using myocardial infarction ECG signals. Computer Methods and Programs in Biomedicine. https://doi.org/10.1016/j.cmpb.2022.107308

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.