The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
On the use of a constant phase element (CPE) in electrochemistry
Open accessAbstract
Several techniques can be used to experimentally determine the interfacial capacitance of an electrode, which is a crucial parameter used for quantifying the efficiency of super-capacitors. However, the values obtained from cyclic voltam-metry can be significantly different from those extracted from electrochemical impedance spectroscopy analysis. This is particularly due to the fact that the interface does not behave like an ideal (i
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The analysis of electrode impedances complicated by the presence of a constant phase element
Brug, G. J., van den Eeden, A. L. G., Sluyters-Rehbach, M., & Sluyters, J. H. (1984) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/s0022-0728(84)80324-1 · Cited by 3,718
Determination of effective capacitance and film thickness from constant-phase-element parameters
Hirschorn, B., Orazem, M. E., Tribollet, B., Vivier, V., Frateur, I., & Musiani, M. (2010) · Electrochimica Acta · doi:10.1016/j.electacta.2009.10.065 · Cited by 2,566
Self-citationPerspectives for electrochemical capacitors and related devices
Simon, P., & Gogotsi, Y. (2020) · Nature Materials · doi:10.1038/s41563-020-0747-z · Cited by 2,208
Electrochemical Impedance Spectroscopy
(2016) · Encyclopedia of Membranes · doi:10.1007/978-3-662-44324-8_100089 · Cited by 1,580
Electrochemical impedance spectroscopy
Wang, S., Zhang, J., Gharbi, O., Vivier, V., Gao, M., & Orazem, M. E. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00039-w · Cited by 1,140
Self-citationImpedance Analysis of Electrochemical Systems
Vivier, V., & Orazem, M. E. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00876 · Cited by 615 · cited 2×
“In practice, the measured capacitance depends on the frequency, and to account for such behavior, a constant phase element (CPE) is often assumed/used during analysis of electrochemical impedance spectroscopy (EIS) instead of a pure capacitor [8,9].”
Self-citationHow Do Pseudocapacitors Store Energy? Theoretical Analysis and Experimental Illustration
Costentin, C., Porter, T. R., & Savéant, J.-M. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b14100 · Cited by 397
On the importance of the electric double layer structure in aqueous electrocatalysis
Shin, S.-J., Kim, D. H., Bae, G., Ringe, S., Choi, H., Lim, H.-K., Choi, C. H., & Kim, H. (2022) · Nature Communications · doi:10.1038/s41467-021-27909-x · Cited by 325
On the corrosion mechanism of Mg investigated by electrochemical impedance spectroscopy
Gomes, M. P., Costa, I., Pébère, N., Rossi, J. L., Tribollet, B., & Vivier, V. (2019) · Electrochimica Acta · doi:10.1016/j.electacta.2019.03.080 · Cited by 306
Self-citationXu, J., Mi, C. C., Cao, B., & Cao, J. (2013) · Journal of Power Sources · doi:10.1016/j.jpowsour.2013.01.094 · Cited by 304
Córdoba-Torres, P., Mesquita, T. J., Devos, O., Tribollet, B., Roche, V., & Nogueira, R. P. (2012) · Electrochimica Acta · doi:10.1016/j.electacta.2012.04.020 · Cited by 273
The Origin of the Constant Phase Element
Lasia, A. (2022) · The Journal of Physical Chemistry Letters · doi:10.1021/acs.jpclett.1c03782 · Cited by 271
Allagui, A., Freeborn, T. J., Elwakil, A. S., & Maundy, B. J. (2016) · Scientific Reports · doi:10.1038/srep38568 · Cited by 230
Huang, J., Gao, Y., Luo, J., Wang, S., Li, C., Chen, S., & Zhang, J. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/abc655 · Cited by 204
Analysis of Electrodes Displaying Frequency Dispersion in Mott-Schottky Tests
Harrington, S. P., & Devine, T. M. (2008) · Journal of The Electrochemical Society · doi:10.1149/1.2929819 · Cited by 184
Review of fractional-order electrical characterization of supercapacitors
Allagui, A., Freeborn, T. J., Elwakil, A. S., Fouda, M. E., Maundy, B. J., Radwan, A. G., Said, Z., & Abdelkareem, M. A. (2018) · Journal of Power Sources · doi:10.1016/j.jpowsour.2018.08.047 · Cited by 165
Ge, Y., Xie, X., Roscher, J., Holze, R., & Qu, Q. (2020) · Journal of Solid State Electrochemistry · doi:10.1007/s10008-020-04804-x · Cited by 163
Lai, X., He, L., Wang, S., Zhou, L., Zhang, Y., Sun, T., & Zheng, Y. (2020) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2020.120203 · Cited by 153
Pascual, P. S., Shao‐Horn, Y., & Escudero‐Escribano, M. (2021) · Current Opinion in Electrochemistry · doi:10.1016/j.coelec.2021.100918 · Cited by 133
Schalenbach, M., Durmus, Y. E., Tempel, H., Kungl, H., & Eichel, R. (2021) · Physical Chemistry Chemical Physics · doi:10.1039/d1cp03381f · Cited by 115
Simple circuit equivalents for the constant phase element
Holm, S., Holm, T., & Martinsen, Ø. G. (2021) · PLoS ONE · doi:10.1371/journal.pone.0248786 · Cited by 114
Córdoba-Torres, P. (2016) · Electrochimica Acta · doi:10.1016/j.electacta.2016.12.087 · Cited by 111
Chen, N., Zhang, P., Dai, J., & Gui, W. (2020) · IEEE Access · doi:10.1109/access.2020.2971002 · Cited by 110
Porous Graphene-Carbon Nanotube Scaffolds for Fiber Supercapacitors
Park, H., Ambade, R. B., Noh, S. H., Eom, W., Koh, K. H., Ambade, S. B., Lee, W. J., Kim, S. H., & Han, T. H. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b17908 · Cited by 106
Influence of experimental factors on the constant phase element behavior of Pt electrodes
Martín, M., & Lasia, A. (2011) · Electrochimica Acta · doi:10.1016/j.electacta.2011.02.068 · Cited by 103
Intrinsic limitations of impedance measurements in determining electric double layer capacitances
Wang, H., & Pilon, L. (2011) · Electrochimica Acta · doi:10.1016/j.electacta.2011.12.051 · Cited by 96
Yavarinasab, A., Janfaza, S., Tasnim, N., Tahmooressi, H., Dalili, A., & Hoorfar, M. (2020) · Analytica Chimica Acta · doi:10.1016/j.aca.2020.02.065 · Cited by 53
Tolouei, N. E., Ghamari, S., & Shavezipur, M. (2020) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2020.114598 · Cited by 36
Time-Domain Modeling of Constant Phase Elements for Simulation of Lithium Battery Behavior
Cheng, C. S., Chung, H. S.-H., Lau, R. W.-H., & Hong, K. Y.-W. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2881200 · Cited by 30
Allagui, A., Alnaqbi, H., Elwakil, A. S., Said, Z., Hachicha, A. A., Wang, C., & Abdelkareem, M. A. (2020) · Applied Physics Letters · doi:10.1063/1.5138243 · Cited by 24
Schalenbach, M., Durmus, Y. E., Tempel, H., Kungl, H., & Eichel, R. (2021) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.1c08595 · Cited by 11
Metadata
- Authors
- Gateman, S. M., Gharbi, O., Gomes de Melo, H., Ngo, K., Turmine, M., & Vivier, V.
- Venue
- Current Opinion in Electrochemistry
- Publisher
- Elsevier BV
- Published
- 2022-12
- Volume
- 36
- Pages
- 101133
- ISSN
- 2451-9103 (ISSN-L)
- OpenAlex
- W4295123539
- Cited by
- 265
- References
- 31
- FWCI
- 1.85
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.