The DOI matches its Crossref record.
Poly(dimethyl siloxane) surface modification by low pressure plasma to improve its characteristics towards biomedical applications
Open accessAbstract
Poly(dimethyl siloxane) elastomer, (PDMS) is widely used as a biomaterial. However, PDMS is very hydrophobic and easily colonized by several bacteria and yeasts. Consequently, surface modification has been used to improve its wettability and reduce bacterial adhesion. The aim of this work was to modify the PDMS surface in order to improve its hydrophilicity and bacterial cell repulsion to be used as a biomaterial. Plasma was used to activate the PDMS surface and sequentially promote the attachment of a synthetic surfactant, Pluronic F-68, or a polymer, Poly(ethylene glycol) methyl methacrylate, PEGMA. Bare PDMS, PDMS argon plasma activated, PDMS coated with Pluronic F-68 and PEGMA-grafted PDMS were characterized by contact angle measurements, X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM). The influence of the surface modifications on blood compatibility of the materials was evaluated by thrombosis and haemolysis assays. The cytotoxicity of these materials was tested for mouse macrophages. After modification, AFM results suggest the presence of a distinct layer at the surface and by the contact angle measures it was observed an increase of hydrophilicity. XPS analysis indicates an increase of the oxygen content at the surface as a result of the modification. All the studied materials revealed no toxicity and were found to be non-haemolytic or in some cases slightly haemolytic. Therefore, plasma was found to be an effective technique for the PDMS surface modification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Plasma-assisted surface modification of organic biopolymers to prevent bacterial attachment
Bazaka, K., Jacob, M. V., Crawford, R. J., & Ivanova, E. P. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.12.024 · Cited by 296
Plasma Surface Modification of Biomedical Polymers: Influence on Cell-Material Interaction
Jacobs, T., Morent, R., De Geyter, N., Dubruel, P., & Leys, C. (2012) · Plasma Chemistry and Plasma Processing · doi:10.1007/s11090-012-9394-8 · Cited by 255
Biomedical Applications of Nondegradable Polymers
Subramaniam, A., & Sethuraman, S. (2014) · Natural and Synthetic Biomedical Polymers · doi:10.1016/b978-0-12-396983-5.00019-3 · Cited by 75
Singh, B., Mohan, M., & Kumar, R. (2022) · Food Hydrocolloids for Health · doi:10.1016/j.fhfh.2022.100057 · Cited by 19
Metadata
- Authors
- Pinto, S., Alves, P., Matos, C. M., Santos, A. C., Rodrigues, L. R., Teixeira, J. A., & Gil, M. H.
- Venue
- Colloids and Surfaces B: Biointerfaces
- Publisher
- Elsevier BV
- Published
- 2010-11
- Volume
- 81
- Issue
- 1
- Pages
- 20-26
- ISSN
- 0927-7765 (ISSN-L)
- OpenAlex
- W2103587633
- Cited by
- 166
- References
- 0
- FWCI
- 5.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Poly(dimethyl siloxane) surface modification by low pressure plasma to improve its characteristics towards biomedical applications. https://app.cochat.ai/papers/10.1016/j.colsurfb.2010.06.014
- The paper
- Pinto, S., Alves, P., Matos, C. M., Santos, A. C., Rodrigues, L. R., Teixeira, J. A., & Gil, M. H. (2010). Poly(dimethyl siloxane) surface modification by low pressure plasma to improve its characteristics towards biomedical applications. Colloids and Surfaces B: Biointerfaces. https://doi.org/10.1016/j.colsurfb.2010.06.014
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.