Interference of engineered nanomaterials in flow cytometry: a case study
Open accessAbstract
Nanotechnology is regarded as the enabling technology of the 21st century. However, only a relatively small number of nano-enabled medical and healthcare products finally made their way to the market. There are several reasons why such innovative approaches fail in translation, with one key factor being the uncertainty surrounding their safety assessment. Although well described, interference reactions of engineered nanomaterials (ENM) with classical cytotoxicity assays remain a major source of uncertainty. Flow cytometry is a powerful, widely used, in vitro technique. Its readout is based on the detection of refracted laser light and fluorescence signals. It is therefore susceptible to ENM interference. Here we investigated possible interferences of ENM in the Annexin V/propidium iodide (PI) assay, which quantifies apoptotic and necrotic cell populations by flow cytometry. Two case studies were conducted using either silica or gold nanoparticles differing in size, specific surface area and surface chemistry. Both ENM types were found to cause distinct interference reactions at realistic concentrations. Silica particles induced false-positive signals; however only in the absence of a protein corona and in conjunction with a particular fluorophore combination (FITC/PI). In contrast, gold particles led to complex quenching effects which were only marginally influenced by the presence of proteins and occurred for both fluorophore combinations analyzed. We present a versatile spi…
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
These same particle properties often interfere with experimental test systems.
“However, these same particle properties often interfere with experimental test systems (Wörle-Knirsch et al., 2006; Laurent et al., 2012; Bohmer et al., 2018).”
From In Vitro research Reproducibility: Keeping up High Standards (2019) · cites this paper as Bohmer et al., 2018
Cited by
Sorted by citations
In Vitro research Reproducibility: Keeping up High Standards
Hirsch, C., & Schildknecht, S. (2019) · Frontiers in Pharmacology · doi:10.3389/fphar.2019.01484 · Cited by 161 · see citing works
Self-citation
- Authors
- Bohmer, N., Rippl, A., May, S., Walter, A., Heo, M. B., Kwak, M., Roesslein, M., Song, N. W., Wick, P., & Hirsch, C.
- Affiliations
- Empa (CH)
- École Polytechnique Fédérale de Lausanne (CH)
- Korea Research Institute of Standards and Science (KR)
- Corresponding author
- Hirsch, Cordula
- ORCID
- Venue
- Colloids and Surfaces B: Biointerfaces
- Publisher
- Elsevier BV
- Published
- 2018-12
- Volume
- 172
- Pages
- 635-645
- ISSN
- 0927-7765 (ISSN-L)
- OpenAlex
- W2889804464
- Cited by
- 34
- References
- 0
- Citations by year
- 2026: 7 · 2025: 3 · 2024: 2 · 2023: 1 · 2022: 6 · 2021: 6 · 2020: 5 · 2019: 4
- FWCI
- 1.40
- Type
- journal article
- Language
- en
- Open access
- green
- infoscience.epfl.ch
- Licence
- Locations
- Colloids and Surfaces B Biointerfaces (publishedVersion)
- PubMed (publishedVersion)
- DORA Empa (Swiss Federal Laboratories for Materials Science and Technology (Empa)) (submittedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Funders
- NanoScreen Materials Challenge
- Competence Centre for Materials Science and Technology
- “Nano Material Technology Development Program (2014M3A7B6020163)
- Topics
- Physical Sciences › Materials Science › Materials Chemistry › Nanoparticles: synthesis and applications
- Life Sciences › Immunology and Microbiology › Immunology › Immunotoxicology and immune responses
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Gold and Silver Nanoparticles Synthesis and Applications
- Keywords
- engineered nanomaterials, apoptosis quantification, silica nanoparticles, gold nanoparticles, protein corona, fluorescence quenching, false positive signals
- MeSH terms
- A549 Cells, Blood Proteins, Cell Membrane, Endocytosis, Flow Cytometry, Fluorescent Dyes, Gold, Humans, Silicon Dioxide, Nanotechnology, Nanostructures, Metal Nanoparticles
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review