CoChat

Machine learning classification of medication adherence in patients with movement disorders using non-wearable sensors

Open access
Tucker, Conrad S., Behoora, Ishan, Nembhard, Harriet Black, Lewis, Mechelle, Sterling, Nicholas W., Huang, Xuemei · 2015 · Computers in Biology and Medicine
Cited by 83

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Medication non-adherence is a major concern in the healthcare industry and has led to increases in health risks and medical costs. For many neurological diseases, adherence to medication regimens can be assessed by observing movement patterns. However, physician observations are typically assessed based on visual inspection of movement and are limited to clinical testing procedures. Consequently, medication adherence is difficult to measure when patients are away from the clinical setting. The authors propose a data mining driven methodology that uses low cost, non-wearable multimodal sensors to model and predict patients’ adherence to medication protocols, based on variations in their gait. The authors conduct a study involving Parkinson’s Disease patients that are “on” and “off” their medication in order to determine the statistical validity of the methodology. The data acquired can then be used to quantify patients’ adherence while away from the clinic. Accordingly, this data-driven system may allow for early warnings regarding patient safety. Using whole-body movement data readings from the patients, the authors were able to discriminate between PD patients on and off medication, with accuracies greater than 97% for some patients using an individually customized model and accuracies of 78% for a generalized model containing multiple patient gait data. The proposed methodology and study demonstrate the potential and effectiveness of using low cost, non-wearable hardware and data mining models to monitor medication adherence outside of the traditional healthcare facility. These innovations may allow for cost effective, remote monitoring of treatment of neurological diseases.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.compbiomed.2015.08.012

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 83

Metadata

Authors
Tucker, C. S., Behoora, I., Nembhard, H. B., Lewis, M., Sterling, N. W., & Huang, X.
Venue
Computers in Biology and Medicine
Publisher
Elsevier BV
Published
2015-11
Volume
66
Pages
120-134
ISSN
0010-4825 (ISSN-L)
OpenAlex
W1425868093
Cited by
83
References
4
FWCI
5.40
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Machine learning classification of medication adherence in patients with movement disorders using non-wearable sensors. https://app.cochat.ai/papers/10.1016/j.compbiomed.2015.08.012
The paper
Tucker, C. S., Behoora, I., Nembhard, H. B., Lewis, M., Sterling, N. W., & Huang, X. (2015). Machine learning classification of medication adherence in patients with movement disorders using non-wearable sensors. Computers in Biology and Medicine. https://doi.org/10.1016/j.compbiomed.2015.08.012

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.