Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 217

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Automatic lung nodule detection using a 3D deep convolutional neural network combined with a multi-scale prediction strategy in chest CTs

Gu, Yu, Lu, Xiaoqi, Yang, Lidong, Zhang, Baohua, Yu, Dahua, Zhao, Ying, Gao, Lixin, Wu, Liang, Zhou, Tao·2018·Computers in Biology and Medicine

Abstract

OBJECTIVE A novel computer-aided detection (CAD) scheme for lung nodule detection using a 3D deep convolutional neural network combined with a multi-scale prediction strategy is proposed to assist radiologists by providing a second opinion on accurate lung nodule detection, which is a crucial step in early diagnosis of lung cancer. METHOD A 3D deep convolutional neural network (CNN) with multi-scale prediction was used to detect lung nodules after the lungs were segmented from chest CT scans, with a comprehensive method utilized. Compared with a 2D CNN, a 3D CNN can utilize richer spatial 3D contextual information and generate more discriminative features after being trained with 3D samples to fully represent lung nodules. Furthermore, a multi-scale lung nodule prediction strategy, including multi-scale cube prediction and cube clustering, is also proposed to detect extremely small nodules. RESULT The proposed method was evaluated on 888 thin-slice scans with 1186 nodules in the LUNA16 database. All results were obtained via 10-fold cross-validation. Three options of the proposed scheme are provided for selection according to the actual needs. The sensitivity of the proposed scheme with the primary option reached 87.94% and 92.93% at one and four false positives per scan, respectively. Meanwhile, the competition performance metric (CPM) score is very satisfying (0.7967). CONCLUSION The experimental results demonstrate the outstanding detection performance of the proposed nodule detection scheme. In addition, the proposed scheme can be extended to other medical image recognition fields.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.compbiomed.2018.10.011

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 217

Metadata

Authors
Gu, Y., Lu, X., Yang, L., Zhang, B., Yu, D., Zhao, Y., Gao, L., Wu, L., & Zhou, T.
Venue
Computers in Biology and Medicine
Publisher
Elsevier BV
Published
2018-12
Volume
103
Pages
220-231
ISSN
0010-4825 (ISSN-L)
OpenAlex
W2895992674
Cited by
217
References
6
FWCI
10.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automatic lung nodule detection using a 3D deep convolutional neural network combined with a multi-scale prediction strategy in chest CTs. https://app.cochat.ai/papers/10.1016/j.compbiomed.2018.10.011
The paper
Gu, Y., Lu, X., Yang, L., Zhang, B., Yu, D., Zhao, Y., Gao, L., Wu, L., & Zhou, T. (2018). Automatic lung nodule detection using a 3D deep convolutional neural network combined with a multi-scale prediction strategy in chest CTs. Computers in Biology and Medicine. https://doi.org/10.1016/j.compbiomed.2018.10.011

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.