CoChat

Accuracy of deep learning for automated detection of pneumonia using chest X-Ray images: A systematic review and meta-analysis

Li, Yuanyuan, Zhang, Zhenyan, Dai, Cong, Dong, Qiang, Badrigilan, Samireh · 2020 · Computers in Biology and Medicine
Cited by 135

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

BACKGROUND Recently, deep learning (DL) algorithms have received widespread popularity in various medical diagnostics. This study aimed to evaluate the diagnostic performance of DL models in the detection and classifying of pneumonia using chest X-ray (CXR) images. METHODS PubMed, Embase, Scopus, Web of Science, and Google Scholar were searched in order to retrieve all studies that implemented a DL algorithm for discriminating pneumonia patients from healthy controls using CXR images. We used bivariate linear mixed models to pool diagnostic estimates including sensitivity (SE), specificity (SP), positive likelihood ratio (PLR), negative likelihood ratio (NLR), and diagnostic odds ratio (DOR). Also, the area under receiver operating characteristics curves (AUC) of the included studies was used to estimate the diagnostic value. RESULTS The pooled SE, SP, PLR, NLR, DOR and AUC for DL in discriminating pneumonia CXRs from controls were 0.98 (95% confidence interval (CI): 0.96-0.99), 0.94 (95% CI: 0.90-0.96), 15.35 (95% CI: 10.04-23.48), 0.02 (95% CI: 0.01-0.04), 718.13 (95% CI: 288.45-1787.93), and 0.99 (95% CI: 0.98-100), respectively. The pooled SE, SP, PLR, NLR, DOR and AUC for DL in discriminating bacterial from viral pneumonia using CXR radiographs were 0.89 (95% CI: 0.79-0.94), 0.89 (95% CI: 0.78-0.95), 8.34 (95% CI: 3.75-18.55), 0.13 (95% CI: 0.06-0.26), 66.14 (95% CI: 17.34-252.37), and 0.95 (0.93-0.97). CONCLUSION DL indicated high accuracy performance in classifying pneumonia from normal CXR radiographs and also in distinguishing bacterial from viral pneumonia. However, major methodological concerns should be addressed in future studies for translating to the clinic.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.compbiomed.2020.103898

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 135

Metadata

Authors
Li, Y., Zhang, Z., Dai, C., Dong, Q., & Badrigilan, S.
Venue
Computers in Biology and Medicine
Publisher
Elsevier BV
Published
2020-08
Volume
123
Pages
103898
ISSN
0010-4825 (ISSN-L)
OpenAlex
W3042255588
Cited by
135
References
8
FWCI
2.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of deep learning for automated detection of pneumonia using chest X-Ray images: A systematic review and meta-analysis. https://app.cochat.ai/papers/10.1016/j.compbiomed.2020.103898
The paper
Li, Y., Zhang, Z., Dai, C., Dong, Q., & Badrigilan, S. (2020). Accuracy of deep learning for automated detection of pneumonia using chest X-Ray images: A systematic review and meta-analysis. Computers in Biology and Medicine. https://doi.org/10.1016/j.compbiomed.2020.103898

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.