Accuracy of deep learning for automated detection of pneumonia using chest X-Ray images: A systematic review and meta-analysis
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
BACKGROUND Recently, deep learning (DL) algorithms have received widespread popularity in various medical diagnostics. This study aimed to evaluate the diagnostic performance of DL models in the detection and classifying of pneumonia using chest X-ray (CXR) images. METHODS PubMed, Embase, Scopus, Web of Science, and Google Scholar were searched in order to retrieve all studies that implemented a DL algorithm for discriminating pneumonia patients from healthy controls using CXR images. We used bivariate linear mixed models to pool diagnostic estimates including sensitivity (SE), specificity (SP), positive likelihood ratio (PLR), negative likelihood ratio (NLR), and diagnostic odds ratio (DOR). Also, the area under receiver operating characteristics curves (AUC) of the included studies was used to estimate the diagnostic value. RESULTS The pooled SE, SP, PLR, NLR, DOR and AUC for DL in discriminating pneumonia CXRs from controls were 0.98 (95% confidence interval (CI): 0.96-0.99), 0.94 (95% CI: 0.90-0.96), 15.35 (95% CI: 10.04-23.48), 0.02 (95% CI: 0.01-0.04), 718.13 (95% CI: 288.45-1787.93), and 0.99 (95% CI: 0.98-100), respectively. The pooled SE, SP, PLR, NLR, DOR and AUC for DL in discriminating bacterial from viral pneumonia using CXR radiographs were 0.89 (95% CI: 0.79-0.94), 0.89 (95% CI: 0.78-0.95), 8.34 (95% CI: 3.75-18.55), 0.13 (95% CI: 0.06-0.26), 66.14 (95% CI: 17.34-252.37), and 0.95 (0.93-0.97). CONCLUSION DL indicated high accuracy performance in classifying pneumonia from normal CXR radiographs and also in distinguishing bacterial from viral pneumonia. However, major methodological concerns should be addressed in future studies for translating to the clinic.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
ImageNet classification with deep convolutional neural networks
Krizhevsky, A., Sutskever, I., & Hinton, G. E. (2017) · Communications of the ACM · doi:10.1145/3065386 · Cited by 112,155
Gulshan, V., Peng, L., Coram, M., Stumpe, M. C., Wu, D., Narayanaswamy, A., Venugopalan, S., Widner, K., Madams, T., Cuadros, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.17216 · Cited by 7,697
Identifying Medical Diagnoses and Treatable Diseases by Image-Based Deep Learning
Kermany, D. S., Goldbaum, M., Cai, W., Valentim, C. C. S., Liang, H., Baxter, S. L., McKeown, A., Yang, G., Wu, X., Yan, F., et al. (2018) · Cell · doi:10.1016/j.cell.2018.02.010 · Cited by 4,842
Wang, X., Peng, Y., Lu, L., Lu, Z., Bagheri, M., & Summers, R. M. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.369 · Cited by 4,616
Learning Deconvolution Network for Semantic Segmentation
Noh, H., Hong, S., & Han, B. (2015) · 2015 IEEE International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2015.178 · Cited by 4,422
A Novel Transfer Learning Based Approach for Pneumonia Detection in Chest X-ray Images
Chouhan, V., Singh, S. K., Khamparia, A., Gupta, D., Tiwari, P., Moreira, C., Damaševičius, R., & de Albuquerque, V. H. C. (2020) · Applied Sciences · doi:10.3390/app10020559 · Cited by 753
Deep neural network ensemble for pneumonia localization from a large-scale chest x-ray database
Sirazitdinov, I., Kholiavchenko, M., Mustafaev, T., Yixuan, Y., Kuleev, R., & Ibragimov, B. (2019) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2019.08.004 · Cited by 240
Cited by
Telehealth utilization during the Covid-19 pandemic: a systematic review
Garfan, S., Alamoodi, A. H., Zaidan, B. B., Al-Zobbi, M., Hamid, R. A., Alwan, J. K., Ahmaro, I. Y. Y., Khalid, E. T., Jumaah, F. M., Albahri, O. S., et al. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.104878 · Cited by 369
Jayakumar, S., Sounderajah, V., Normahani, P., Harling, L., Markar, S. R., Ashrafian, H., & Darzi, A. (2022) · npj Digital Medicine · doi:10.1038/s41746-021-00544-y · Cited by 110
Geric, C., Qin, Z. Z., Denkinger, C. M., Kik, S. V., Marais, B., Anjos, A., David, P.-M., Ahmad Khan, F., & Trajman, A. (2023) · The International Journal of Tuberculosis and Lung Disease · doi:10.5588/ijtld.22.0687 · Cited by 61
Dutta, K., Lenka, R., Gupta, P., Goel, A., & Naga Ramesh, J. V. (2024) · EAI Endorsed Transactions on Pervasive Health and Technology · doi:10.4108/eetpht.10.5581 · Cited by 1
“In this context, incorporating machine learning and deep learning models [7][8], such as the one presented in this research, remains invaluable.”
Background
Metadata
- Authors
- Li, Y., Zhang, Z., Dai, C., Dong, Q., & Badrigilan, S.
- Venue
- Computers in Biology and Medicine
- Publisher
- Elsevier BV
- Published
- 2020-08
- Volume
- 123
- Pages
- 103898
- ISSN
- 0010-4825 (ISSN-L)
- OpenAlex
- W3042255588
- Cited by
- 135
- References
- 8
- FWCI
- 2.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of deep learning for automated detection of pneumonia using chest X-Ray images: A systematic review and meta-analysis. https://app.cochat.ai/papers/10.1016/j.compbiomed.2020.103898
- The paper
- Li, Y., Zhang, Z., Dai, C., Dong, Q., & Badrigilan, S. (2020). Accuracy of deep learning for automated detection of pneumonia using chest X-Ray images: A systematic review and meta-analysis. Computers in Biology and Medicine. https://doi.org/10.1016/j.compbiomed.2020.103898
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.