Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 165

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

A robust real-time deep learning based automatic polyp detection system

Pacal, Ishak, Karaboga, Dervis · 2021 · Computers in Biology and Medicine

Abstract

Colorectal cancer (CRC) is globally the third most common type of cancer. Colonoscopy is considered the gold standard in colorectal cancer screening and allows for the removal of polyps before they become cancerous. Computer-aided detection systems (CADs) have been developed to detect polyps. Unfortunately, these systems have limited sensitivity and specificity. In contrast, deep learning architectures provide better detection by extracting the different properties of polyps. However, the desired success has not yet been achieved in real-time polyp detection. Here, we propose a new structure for real-time polyp detection by scaling the YOLOv4 algorithm to overcome these obstacles. For this, we first replace the whole structure with Cross Stage Partial Networks (CSPNet), then substitute the Mish activation function for the Leaky ReLu activation function and also substituted the Distance Intersection over Union (DIoU) loss for the Complete Intersection over Union (CIoU) loss. We improved performance of YOLOv3 and YOLOv4 architectures using different structures such as ResNet, VGG, DarkNet53, and Transformers. To increase success of the proposed method, we utilized a variety of data augmentation approaches for preprocessing, an ensemble learning model, and NVIDIA TensorRT for post processing. In order to compare our study with other studies more objectively, we only employed public data sets and followed MICCAI Sub-Challenge on Automatic Polyp Detection in Colonoscopy. The proposed method differs from other methods with its real-time performance and state-of-the-art detection accuracy. The proposed method (without ensemble learning) achieved higher results than those found in the literature, precision: 91.62%, recall: 82.55%, F1-score: 86.85% on public ETIS-LARIB data set and precision: 96.04%, recall: 96.68%, F1-score: 96.36% on public CVC-ColonDB data set, respectively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.compbiomed.2021.104519

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 165

Metadata

Authors
Pacal, I., & Karaboga, D.
Venue
Computers in Biology and Medicine
Publisher
Elsevier BV
Published
2021-07
Volume
134
Pages
104519
ISSN
0010-4825 (ISSN-L)
OpenAlex
W3167977644
Cited by
165
References
13
FWCI
9.46
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A robust real-time deep learning based automatic polyp detection system. https://app.cochat.ai/papers/10.1016/j.compbiomed.2021.104519
The paper
Pacal, I., & Karaboga, D. (2021). A robust real-time deep learning based automatic polyp detection system. Computers in Biology and Medicine. https://doi.org/10.1016/j.compbiomed.2021.104519

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.