Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 159

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

An efficient real-time colonic polyp detection with YOLO algorithms trained by using negative samples and large datasets

Pacal, Ishak, Karaman, Ahmet, Karaboga, Dervis, Akay, Bahriye, Basturk, Alper, Nalbantoglu, Ufuk, Coskun, Seymanur · 2022 · Computers in Biology and Medicine

Abstract

Colorectal cancer (CRC) is one of the common types of cancer with a high mortality rate. Colonoscopy is the gold standard for CRC screening and significantly reduces CRC mortality. However, due to many factors, the rate of missed polyps, which are the precursors of colorectal cancer, is high in practice. Therefore, many artificial intelligence-based computer-aided diagnostic systems have been presented to increase the detection rate of missed polyps. In this article, we present deep learning-based methods for reliable computer-assisted polyp detection. The proposed methods differ from state-of-the-art methods as follows. First, we improved the performances of YOLOv3 and YOLOv4 object detection algorithms by integrating Cross Stage Partial Network (CSPNet) for real-time and high-performance automatic polyp detection. Then, we utilized advanced data augmentation techniques and transfer learning to improve the performance of polyp detection. Next, for further improving the performance of polyp detection using negative samples, we substituted the Sigmoid-weighted Linear Unit (SiLU) activation functions instead of the Leaky ReLU and Mish activation functions, and Complete Intersection over Union (CIoU) as the loss function. In addition, we present a comparative analysis of these activation functions for polyp detection. We applied the proposed methods on the recently published novel datasets, which are the SUN polyp database and the PICCOLO database. Additionally, we investigated the proposed models for MICCAI Sub-Challenge on Automatic Polyp Detection in Colonoscopy dataset. The proposed methods outperformed the other studies in both real-time performance and polyp detection accuracy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.compbiomed.2021.105031

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 159

Metadata

Authors
Pacal, I., Karaman, A., Karaboga, D., Akay, B., Basturk, A., Nalbantoglu, U., & Coskun, S.
Venue
Computers in Biology and Medicine
Publisher
Elsevier BV
Published
2022-02
Volume
141
Pages
105031
ISSN
0010-4825 (ISSN-L)
OpenAlex
W3212769770
Cited by
159
References
11
FWCI
8.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An efficient real-time colonic polyp detection with YOLO algorithms trained by using negative samples and large datasets. https://app.cochat.ai/papers/10.1016/j.compbiomed.2021.105031
The paper
Pacal, I., Karaman, A., Karaboga, D., Akay, B., Basturk, A., Nalbantoglu, U., & Coskun, S. (2022). An efficient real-time colonic polyp detection with YOLO algorithms trained by using negative samples and large datasets. Computers in Biology and Medicine. https://doi.org/10.1016/j.compbiomed.2021.105031

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.