Microbiologically induced corrosion of concrete in sewer structures: A review of the mechanisms and phenomena
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Microbiologically induced corrosion (MIC) is a century old problem facing global concrete sewer structures. Despite the substantial efforts that have been made, MIC of concrete sewers remains a highly debated subject. To further advances our understanding on the problem, we need to know the existing knowledge. In light of this, we intend to provide a state-of-the-art review on the subject. By acknowledging the complexity and broadness of the concerned problem and in order to discuss relevant aspects in depth, the scope of the current work is limited to the key elements of the mechanisms and phenomena observed on site investigations and laboratory studies for MIC of concrete sewers. In general, four main events have been considered accounting for the MIC process, i.e. formation of hydrogen sulfide in the waste steam, radiation and buildup of gaseous hydrogen sulfide, generation of sulfuric acid and deterioration of the concrete materials. Fundamentals associated with the main events, especially the important influencing factors, are reviewed and discussed. Based on site investigations and laboratory studies, several aspects of the MIC phenomena are summarized, including corrosion areas, corrosion rates, impact of cement and aggregate types. It is worth mentioning that the corrosion rates obtained on site and laboratory studies generally vary a lot, which may be attributed to different testing conditions and procedures. The fact that standard testing or evaluation methods are missing also complicates the issue. In addition, it seems difficult to establish quantitative relations between the corrosion behavior observed on site and that obtained in laboratory studies, at least based on the existing knowledge. This highlights the need for further research to advance our understanding on different aspects related to MIC of concrete sewers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Depth Penetration and Detection of pH Gradients in Biofilms by Two-Photon Excitation Microscopy
Vroom, J. M., De Grauw, K. J., Gerritsen, H. C., Bradshaw, D. J., Marsh, P. D., Watson, G. K., Birmingham, J. J., & Allison, C. (1999) · Applied and Environmental Microbiology · doi:10.1128/aem.65.8.3502-3511.1999 · Cited by 303
Metadata
- Authors
- Wu, M., Wang, T., Wu, K., & Kan, L.
- Venue
- Construction and Building Materials
- Publisher
- Elsevier BV
- Published
- 2020-04
- Volume
- 239
- Pages
- 117813
- ISSN
- 0950-0618 (ISSN-L)
- OpenAlex
- W2998180719
- Cited by
- 190
- References
- 1
- FWCI
- 5.30
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microbiologically induced corrosion of concrete in sewer structures: A review of the mechanisms and phenomena. https://app.cochat.ai/papers/10.1016/j.conbuildmat.2019.117813
- The paper
- Wu, M., Wang, T., Wu, K., & Kan, L. (2020). Microbiologically induced corrosion of concrete in sewer structures: A review of the mechanisms and phenomena. Construction and Building Materials. https://doi.org/10.1016/j.conbuildmat.2019.117813
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.