Structural health monitoring (SHM) and Nondestructive testing (NDT) of slender masonry structures: A practical review
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The scientific community is hardly working to propose reliable methodologies of analysis and non-invasive technologies of investigation to assess the current state of conservation of historic buildings to verify their ability to resist future threats. These structures, mostly made of masonry, are difficult to assess due to the heterogeneity of materials and their mechanical behavior, but it is vital to preserve this invaluable cultural heritage by suitable structural assessment techniques. A great deal of research attention has been paid to monitoring their structural health; in many recent publications new advanced technological methods have been provided such as cheaper sensors, wireless connections, non-contact surveys and continuous monitoring. A bibliometric study has shown that more than half of the papers on Structural Health Monitoring (SHM) and Nondestructive Testing (NDT) on masonry have been published between 2018 and 2020, and 30% of those published in 2020 were on ‘slender’ elements like towers, chimneys or minarets. This paper presents a wide-ranging review of static and dynamic studies published on SHM and NDT of slender masonry structures summarizing and discussing the different experimental techniques used. With respect to the dynamic testing, Operational Modal Analysis (OMA) by accelerometers is the mostly frequent used technique by scholars, but other promising methods such as radar interferometry are also reported. This overall discussion is concluded with a short review of some examples on numerical structural health assessment and signal processing tools. An inclusive list of papers is provided describing the most important slender masonry structures characteristics, natural frequencies, experimental and numerical techniques employed and reference values. This paper, set on a practical perspective, is expected to be of interest to those researchers and practitioners who require an extensive and up-to-date review of this topic.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magalhães, F., Cunha, A., & Caetano, E. (2012) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2011.06.011 · Cited by 655
Monitoring historical masonry structures with operational modal analysis: Two case studies
Ramos, L. F., Marques, L., Lourenço, P. B., De Roeck, G., Campos-Costa, A., & Roque, J. (2010) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2010.01.011 · Cited by 443 · cited 4×
“When used continuously, SHM can evaluate the effects of interventions or damage assessment [7].”
BackgroundMethodInfluential
Cited by
Sakr, M., & Sadhu, A. (2023) · Journal of Infrastructure Intelligence and Resilience · doi:10.1016/j.iintel.2023.100053 · Cited by 46
Metadata
- Authors
- Pallarés, F. J., Betti, M., Bartoli, G., & Pallarés, L.
- Venue
- Construction and Building Materials
- Publisher
- Elsevier BV
- Published
- 2021-08
- Volume
- 297
- Pages
- 123768
- ISSN
- 0950-0618 (ISSN-L)
- OpenAlex
- W3171587486
- Cited by
- 218
- References
- 2
- FWCI
- 18.28
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.